GX-Series Control Panel Installation and Setup Guide
6-20
Option 41 ā Time/Date [Quick Menu Option 7]
The Time/Date option can be accessed and modified by type 3.6 codes, the Engineer and the remote code. If
any groups are locked, then the time and date cannot be modified.
Modifying the Time and Date
The Time/Date option allows the system time and date to be modified. On entering this option the display
prompts for selection A = TIME B = DATE. Press the A> key to select the time option; this allows a new
time to be entered. The time must be a valid four digit number ā in the 24 hour format (hh:mm). The entry,
if valid, will be accepted immediately and the display is returned to the selection screen. Press the <B key to
select the date option; this allows a new date to be entered. The date must be a valid 6 digit number - in the
day, month and year format (dd/mm/yy). The date entry, if valid, will be accepted immediately and the
display is returned to the selection screen.
NOTE: The time and date can be modified when groups are set (armed).
Adjusting the Clock Speed
Variations in the accuracy of the clock speed can be compensated by pressing the # key while the A = TIME
B = DATE selection screen in the Time/Date menu is displayed. The keypad prompts for the Adjustment/
Week, in seconds, to be entered; the range is 0 ā 120 seconds. If the clock needs to gain time, enter the
required number of seconds. If the clock needs to lose time, enter the required number of seconds and press
the * key; the * slows the clock speed.
Option 42 ā Codes [Quick Menu Option 8]
The Codes option is used to assign, modify and delete the codes that allow users to operate and access the
system. The Codes option is divided into three sub-menus:
1 = User Codes - sub-divided into up to 11 menus (depending on panel used and whether the group and
MAX mode options are enabled in Menu 63) that determine all of the access information for users
who are requiring PINs. This option also assigns MAX details to user numbers;
2 = PIN Warning - determines the warning period given to users prior to the programmed PIN
Change date (refer to option 51.42 = PARAMETER.PIN Change);
3 = Card Users - determines the proximity cards on the system for various users.
Programming Codes
1 = User Codes
1 = Modify Pin
4, 5 or 6 digit pin
2 = Modify Level
3 = Modify Name
4 = Schedule
1.0 to 3.6
6 alpha-numeric characters
5 = Temp Code 00-99 days
6 = Modify Groups
GD-48: 1-4
GD-520: 1-32
7 = Card Number
10 digit number on access control card or fob
8 = MAX Function number of required menu option
9 = MAX Keypad
address of keypad that MAX function displays on
10 = APB Forgive
This function clears passback restrictions
2 = PIN Warning 1 - 28 days
3 = Card Users
1 = Add Batch
2 = Test Batch
3 = Delete Batch
4 = Batch Start
5 = Batch End
6 = Batch DCM Rdr
7 = Template User
(00=None)
11 = Template
GX-050-V1
Figure 6-2. Programming Codes
NOTE:
MAX = Access Control Reader