GX-Series Control Panel Installation and Setup Guide
2-4
+12V
+12V
+12V
+12V
A2
GND
+12V
B2
A1
RTS
CTS
RX
TX
GND
+12V
B1
A
B
A
B
1
2
0V
0V
0V
0V
0V
3
4
0V
RIO 0
RIO 1
5
6
7
8
1
2
3
4
5
6
7
8
BLUE
BLUE
BLACK
INPUT RATING
120VAC, 60 Hz
1.0A MAX
CONNECT TO
A DEDICATED
CIRCUIT
TAMPER SWITCH
FOR EXAMPLE
ON EXTERNAL
SIREN
LOUND
SPEAKER
8-32Ω
DETAIL
DOOR AND REAR TAMPER
(CONNECT AS SHOWN)
SEE DETAIL
BELOW
WHITE
2A
INCOMING
TELEPHONE
LINE
RS232
CONNECTION
TO PC SERIAL
COM PORT
RS485
LINE 2
(NOTE 1)
RS485
LINE 1
(NOTE 1)
PREMISES
TELEPHONE
+BAT
-BAT
MODEL 1451
TRANSFORMER
OFF WALL
TAMPER
LK2
BATTERY
STARTUP
LK4
LINE
PHONE
RTS
CTS
RX
TX
PANEL TERMINALS
DATA BUS
CONNECTION
FOR PERIPHERAL
MODULES
(MK7 KEYPAD
TOUCHCENTER,
RIO EXPANDER,
ETHERNET MODULE
(LINE 1 ONLY)
DOOR CONTROL
MODULE)
ALTERNATE PHONE
LINE CONNECTION FOR
RJ11 CONNECTORS
MICRO
PROCESSOR
LK5 RS485 LINE 1, 680 Ω TERMINATION
(NOTE 2)
1 K Ω
1 K Ω
1 K Ω
1 K Ω
LK3 RS485 LINE 2, 680 Ω TERMINATION
(NOTE 2)
RS232 PORT SOCKET
FOR CABLE A234
ENGINEER SOCKET
(RS485 LINE 2)
TRIGGER HEAD
(SEE TABLE 1)
ENGINEER SOCKET
(RS485 LINE 1)
LED 1 (FOR TELECOMS)
LED 2 (FOR TELECOMS)
12
1
RIO
SWITCH
2 34561
ON
78
N/C
N/C
N/0
PULL-UP (DIP) SWITCHES
SW 3
LOUD SPEAKER
HORN OUTPUT
VOLUME CONTROL
GND
AUX TAMP
2 341
2341
RIO 1RIO 0
POWERED
DETECTOR
RELAY
OUTPUT
16 ON-BOARD ZONES
0V0V
ZONE WIRING
(FOR ALL ZONE PAIRS)
(TYPICAL)
9-WAY D-TYPE
CONNECTOR
(FEMALE)
(SEE TABLE 2)
CONNECTION OUTPUT ADDRESS MAX. OUTPUTPIN
TRIGGER 2 00028 100 mA
TRIGGER 3 00037 100 mA
TRIGGER 4 00046 100 mA
TRIGGER 5 00055 100 mA
0V GND N/A12 N/A
NOT USED N/A11 N/A
NOT USED N/A10 N/A
TRIGGER 1 00019 100 mA
TRIGGER 6 00064 100 mA
NOT USED N/A3 N/A
NOT USED N/A2 N/A
+12V N/A 100 mA1
9W-D SIGNAL NAME
PIN 6 SHORT TO PIN 4
PIN 4 SHORT TO PIN 6
PIN 2 Tx
PIN 3 Rx
PIN 7 CTS
PIN 8 RTS
PIN 5 GROUND
GX-SOC-V4
RS485 DATA BUS LINES MUST USE DAISY CHAIN WIRING BETWEEN MODULES.NOTE 1:
ALARM
CONTACT
ALARM
CONTACT
TABLE 1 - TRIGGER HEAD
‡
TABLE 2 - RS232 CONNECTIONS
LED (LED 1) STATE INDICATION
Flashes in time with ringing signal Line Ringing
The on-board Telecom Module monitors the PSTN line
under normal idle state conditions. LED 1 indicates the
communications status.
Pulses as each digit is dialed Normal indication when
making a call
Flickering during alarm monitoring,
Remote servicing and SMS
Poor Communication
On during alarm monitoring,
Remote Servicing and SMS
Normal Communication
Flashing at end of alarm call Failed Communication
Single pulse at end of call Normal Communication
On - 01s, Off- 0.9s Normal Communication
LED Off No DC supply
TABLE 3 - COMMUNICATION STATUS
LED STATE INDICATION
LED 2 Flashes Ethernet Module sending or receiving data
LED 2 OFF No Communication on RS232 line
LED 2 ON Communication between Control Panel and PC
LED 1 ON Ethernet Module connected to Ethernet
TABLE 4 -
ETHERNET
COMMUNICATION
STATUS
TIP
RING
TIP
RING
GX SERIES
SUMMARY OF CONNECTIONS
RS485 EXPANSION
MODULE STANDOFF
SWITCHED 0V OUTPUTS
AUX 3
12V POWERED LOAD. EG: SIREN,
WARNING LAMP, ELECTRONIC
LOCK, ETC. FOR ALL SWITCHED
0V OUTPUTS
+12V
SPI
PROGRAM
HEADER
TAMPER
SWITCH
(OPTIONAL)
WARNING: TO PREVENT RISK
OF SHOCK DISCONNECT
TELEPHONE LINES AT TELCO
JACK BEFORE SERVICING
THIS UNIT.
AC
LID
TAMPER 1
LID
TAMPER 2
RS-485
EXPANSION
MODULE
GX-520
ONLY
BROWN
GREY
GREEN
RED
JUMPER MUST BE INSTALLED
DO NOT PLACE JUMPER
OVER 2 PINS.
DEVELOPMENT PURPOSE ONLY
ALL CIRCUITS ARE
POWER LIMITED
EXCEPT THE OUTPUT OF
1451 TRANSFORMER
AND THE BATTERY.
LID
TAMPER
1
LID
TAMPER
2
* TB1 * TB2 * TB3 * TB4
12V 7AH BATTERY
CAPACITY IS
REQUIRED FOR
EMERGENCY
STANDBY FOR AT
LEAST 4 HOURS
FOR UL
INSTALLATIONS
TWO 12V 7AH BATTERIES
ARE REQUIRED
UL Applications: Proprietary,
Commercial Central Station,
Local Mercantile Burglar Alarm,
Access Control Unit, Standard
Line Security, Dual Line
Transmission via PSDN and
DACT
NOTE: MAINTAIN
1/4" SEPARATION
OF POWER LIMITED
AND NON-POWER
LIMITED CIRCUITS
IC: 573F-GXSERIES
NOTE 5: FOR UL INSTALLATIONS, 26AWG CABLE (MINIMUM) IS REQUIRED FOR TELECO
CONNECTIONS.
NOTE 4: FOR MORE INFORMATION, REFER TO THE FOLLOWING DOCUMENTS:
QUICK INSTALLATION INSTRUCTIONS (P/N 800-05372 REV A)
INSTALLATION INSTRUCTIONS (P/N 800-05928 REV A)
NOTE 3: WIRING METHOD SHALL BE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE
[ANSI/NFPA70], LOCAL CODES, AND THE AUTHORITIES HAVING JURISDICTION.
NOTE 2: EACH END OF THE RS485 DATA BUS MUST BE TERMINATED WITH A 680 OHM
RESISTOR ACROSS THE A&B WIRES. IF THE PANEL DOES NOT FORM ONE END
OF THE BUS, REMOVE THE LINK TO DISABLE THE 680 OHM RESISTOR.
‡ NOT EVALUATED BY UL.
‡
* FOR TB1 - TB4: USE
EOL RESISTOR (1KOHM)
P/N 300-02343 SUPPLIED
IN SAP0166 PACKAGE
FOR UL INSTALLATIONS.
(NOTE 5)
MEMORY
BACKUP
BATTERY
2XRS485
EXPANSION CARD
INTERFACE
BACKUP LITHIUM
BATTERIES ARE TO
BE REPLACED BY
TRAINED SERVICE
PERSONNEL ONLY.
NOTE: MAXIMUM LOAD
FOR LOUD SPEAKER IS
100 mA DC WITH SPEAKER
IMPEDANCE OF 8Ω
ZONES 1-8 (RIO 0 LINE 1)
ZONES 1-8 (RIO 1 LINE 0
SWITCH 3-8 ON)
OR
ZONES 1-8 (RIO 1 LINE 1
SWITCH SW3-8 OFF)
** TB5 ** TB6
Memory backup battery replacement:
1. Remove memory backup
battery with a small flat
head screwdriver.
2. Replace with good battery.
3. Reconnect mains supply.
4. Reconnect 12V battery.
* NOTES: FOR TB1 - TB4: USE
EOL RESISTOR (1KOHM)
P/N 300-02343 SUPPLIED
IN SAP0166 PACKAGE FOR
UL INSTALLATIONS;
TOTAL MAXIMUM CURRENT
DRAW FOR THE +12V AUX
OUTPUTS = 1A.
**NOTE: FOR TB5 AND TB6: TOTAL MAXIMUM CURRENT
DRAW FOR THE SWITCHED AUX OUTPUTS = 400mA.
Figure 2-4. PCB Layout