EasyManuals Logo
Home>Honeywell>Control Panel>GX-Series

Honeywell GX-Series User Manual

Honeywell GX-Series
208 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #192 background imageLoading...
Page #192 background image
GX-Series Control Panel Installation and Setup Guide
B-8
Ev SIA Event Log Log Event Ev Type Contact
Description Event Description Trigger ID
Event
WT Trouble LOW RES+ Low resistance on zone ZONE 15.TROUBL 380
HIGH RES+ High resistance on zone ZONE 15.TROUBL 380
WU Unbypass FORCE OMT- Unomitted after rearm ZONE 8.OMIT 573
Z - Freezer (Custom SIA - see note 2)
ZA Alarm Note 1 zone in alarm ZONE 5.CUS ZON Note 1
ZB Bypass OMITTED zone omitted ZONE 8.OMIT 573
FORCEOMT+ Force omit after rearm ZONE 8.OMIT 573
ZJ Trouble Rest LOW RES- Restor zone resistance ZONE 15.TROUBL 380
HIGH RES- Restor zone resistance ZONE 15.TROUBL 380
ZR Alarm Restore Note 1 zone restored ZONE 5.CUS ZON Note 1
18.ZN RESTO
ZT Trouble LOW RES+ Low resistance on zone ZONE 15.TROUBL 380
HIGH RES+ High resistance on zone ZONE 15.TROUBL 380
ZU Unbypass FORCE OMT- Unomitted after rearm ZONE 8.OMIT 573
NOTES: 1 Dependent upon zone type selected
2 Custom SIA event allow existing zone types to be modified in order to send specific SIA events from the panel. This allows more
specific SIA information to be transmitted. The zones used to program the custom SIA events will continue to function as per the
zone description

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell GX-Series and is the answer not in the manual?

Honeywell GX-Series Specifications

General IconGeneral
BrandHoneywell
ModelGX-Series
CategoryControl Panel
LanguageEnglish

Related product manuals