Select Mounting information from the menu, then select the guide titled Mounting in non-HP
racks.
Pedestal kit installation
The server ships with a pedestal mount if you order the rackless configuration option. The pedestal
mount is packaged in a separate carton that is attached to the server carton.
To change the server from a rack-mount to a rackless configuration, you need a pedestal kit. The
pedestal mount kit comes with the Pedestal Kit Installation Guide for HP Integrity rx2800 i2 and
HP Proliant DL380 G6 & DL385 G6 Servers. Follow the steps in this installation guide to attach
the pedestal to the server.
Connecting server cables
AC input power
The server can receive ac input from two different ac power sources. The power receptacles are
located at the rear of the server.
A maximum of two power supplies can be installed in the server. Installing two power supplies in
the server provides 1+1 redundancy, meaning that if one power supply fails, there is still enough
power supplied to the server to operate. You must promptly replace the failed power supply to
restore 1+1 functionality.
All high-line (220 V) configurations are capable of 1+1 redundancy. Low-line (110 V) configurations
can maintain 1+1 redundancy as long as the total power consumed does not exceed 800 W.
A minimum of one power supply is required to power the server. If only one power supply is
installed in the server, there is no 1+1 capability.
Power states
The server has the following power states:
• Standby power
• Full power
• Off
Table 16 Power states
dc voltage
applied?
Standby dc
voltage applied?
Power activated through the iLO 3PC
command; or front panel power button
activated?
Power cable
plugged into
receptacle?
Power states
NoYesNoYesStandby power
YesYesYesYesFull power
NoNoNoNoOff
CAUTION: If the server is expected to remain in standby mode for more than 30 minutes, ac
power should be completely removed from the server. You can do this by switching off the circuit
breakers that are part of the building installation, disconnecting or switching off a power distribution
unit, or by physically removing the power cords from the server.
NOTE: If the power restore feature is set to Always On through the iLO 3 MP PR command, the
server automatically powers on to the full power state when the power cord is plugged in to the
server.
Figure 10 (page 20) shows the ports and power supplies located on the rear panel of the server.
Connecting server cables 45

Table of Contents

Other manuals for HP Integrity rx2800 - i2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP Integrity rx2800 - i2 and is the answer not in the manual?

HP Integrity rx2800 - i2 Specifications

General IconGeneral
BrandHP
ModelIntegrity rx2800 - i2
CategoryServer
LanguageEnglish

Related product manuals