128
Notification Triggering condition Remarks
Minor alarm-removed
notification
The amount of free memory
space increases to or above the
normal state threshold.
N/A
Figure 37 Memory alarm notification and alarm-removed notification
To set memory thresholds:
Step Command Remarks
1. Enter system view.
system-view
N/A
2. Set free-memory
thresholds.
memory-threshold [ slot slot-number
[ cpu cpu-number ] ] minor minor-value
severe severe-value critical
critical-value normal normal-value
The defaults are as follows:
• Minor alarm threshold—96 MB.
• Severe alarm threshold—64
MB.
• Critical alarm threshold—48
MB.
• Normal state threshold—128
MB.
3. Set the memory
usage threshold.
memory-threshold [ slot slot-number
[ cpu cpu-number ] ] usage
memory-threshold
By default, the memory usage
threshold is 100%.
Configuring the temperature alarm thresholds
The device monitors its temperature based on the following thresholds:
• Low-temperature threshold.
• High-temperature warning threshold.
• High-temperature alarming threshold.
The device monitors its own temperature through temperature sensors, based on the following
thresholds:
• Low-temperature threshold.
• High-temperature warning threshold.
• High-temperature alarming threshold.
Minor
Critical
Free memory space
Severe
Normal
Minor alarm-removed
Severe alarm-removed
Time
Minor
alarm
Severe alarm
Critical alarm
Critical alarm-removed