Step Command Remarks
line class view.
5. Specify the
number of stop
bits.
stopbits
{
1
|
1.5
|
2
}
The default is 1.
Stop bits indicate the end of a character.
The more the stop bits, the slower the
transmission.
This command is not available in AUX
line class view.
6. Specify the
number of data
bits for each
character.
databits
{
5 | 6 | 7
|
8
}
The default is 8.
The setting varies by character coding
type. For example, you can set it to 7 if
standard ASCII characters are to be sent.
If extended ASCII characters are to be
sent, set it to 8.
This command is not available in AUX
line class view.
7. Define a shortcut
key for starting a
terminal session.
activation-key
character
By default, pressing
Enter
starts the
terminal session.
8. Define a shortcut
key for terminating
tasks.
escape-key
{ character |
default
}
By default, pressing
Ctrl+C
terminates a
task.
9. Configure the flow
control mode.
flow-control
{
hardware
|
none
|
software
}
This command is not available in AUX
line class view.
By default, the flow control mode is
none
.
10. Specify the
terminal display
type.
terminal type
{
ansi | vt100
}
By default, the terminal display type is
ANSI.
The device supports ANSI and VT100
terminal display types. As a best practice,
set the display type to VT100 on both the
device and the configuration terminal. If
either side uses the ANSI type, a display
problem such as cursor positioning error
might occur when a command line has
more than 80 characters.
11. Set the maximum
number of lines to
be displayed on a
screen.
screen-length
screen-length
By default, a screen displays up to 24
lines.
A value of 0 disables pausing between
screens of output.
12. Set the size of the
command history
buffer.
history-command max-size
value
By default, the buffer saves up to 10
history commands.
13. Set the CLI
connection
idle-timeout timer.
idle-timeout
minutes
[
seconds
]
By default, the CLI connection
idle-timeout timer is 10 minutes.
If no interaction occurs between the
device and the user within the
idle-timeout interval, the system
automatically terminates the user
connection on the user line.
If you set the timeout timer to 0, the
connection will not be aged out.

Table of Contents

Other manuals for HPE FlexNetwork 5130 EI Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HPE FlexNetwork 5130 EI Series and is the answer not in the manual?

HPE FlexNetwork 5130 EI Series Specifications

General IconGeneral
BrandHPE
ModelFlexNetwork 5130 EI Series
CategorySwitch
LanguageEnglish

Related product manuals