Loading...
Item LED Status Definition
1 Fault
\Locate
Solid amber The drive has failed.
Solid blue The drive is operating normally and being identified by a
management application.
Flashing amber/blue
(1 flash per second)
The drive has failed, or a predictive failure alert has been received for
this drive; it also has been identified by a management application.
Flashing amber
(1 flash per second)
A predictive failure alert has been received for this drive. Replace the
drive as soon as possible.
2 Online
\Activity
Solid green The drive is online and has no activity.
Flashing green
(4 flashes per second)
The drive is operating normally and has activity.
Flashing green
(1 flash per second)
The drive is doing one of the following:
Rebuilding
Performing a RAID migration
Performing a strip size migration
Performing a capacity expansion
Performing a logical drive extension
Erasing
Spare part activation
O
The drive is not configured by a RAID controller or a spare drive.
Hot-plug drive LED definitions
Item
LED Status Definition
1 Locate Solid blue The drive is being identified by a host application.
Flashing blue The drive carrier firmware is being updated or requires an update.
Table Continued