This change is indicated by the Health LED flashing amber. The system continues to operate normally in this mode.
• A second fan rotor failure or a missing fan causes the operating system to orderly shutdown.
Installing a fan
This server supports redundant fans to provide suicient airflow to the system if a fan rotor fails.
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system
components to cool before touching them.
CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are
populated with either a component or a blank.
Procedure
1. Extend the server from the rack.
2.
Remove the access panel.
3. To determine which fan blanks must be removed to install the additional fans, see Fan bay numbering.
4.
Remove the fan blank.
5. Install the fan.
Hardware options installation
99