13. Install the secondary riser cage:
a. Align the arrows on the riser cage with the arrows on the power supply cage. (callout 1)
b. Press the riser cage down to sit it firmly in the slot. (callout 1)
c. Turn the captive screw to 180 °. (callout 2)
d. Push the screw handle down in horizontal position. (callout 3)
14.
Install the access panel.
15.
Install the server into the rack.
16.
Connect all peripheral cables to the server.
17.
Connect each power cord to the server.
18.
Connect each power cord to the power source.
19.
Power up the server.
20.
If removed,
install the bezel.
The installation is complete.
Storage controller options
This server supports the following storage controllers:
For SATA and NVMe drives : Embedded controller in AHCI mode
For SAS, SATA, and uFF drives:
Smart Array type-a modular controller
Smart Array PCIe plug-in controller
Installing a Smart Array type-a modular controller
Prerequisites
Before you perform this procedure, make sure that you have the following items available: