16SFF SAS/SATA
16SFF NVMe
12. Install eight dual rotor fans included in this 8SFF to 16SFF upgrade option.
13. Install the air bale included in this 8SFF to 16SFF upgrade option.
14. Install the inner drive cage.
15. Install the access panel.
16. Install the inner rack rails.
17. Install the server into the rack.
18. Connect all peripheral cables to the server.
19. Connect each power cord to the server.
20. Connect each power cord to the power source.
21.
Power up the server.
22.
If removed, install the bezel.
The installation is complete.
Riser cage options
Installing the secondary low profile PCIe riser cage
When installed, this riser cage provides an additional low profile slot and supports half-height/half-length expansion
boards.
Procedure
1.
If installed,
remove the bezel.
2.
Power down the server.
3.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
4. Disconnect all peripheral cables from the server.
5.
Remove the server from the rack.
6. Remove the access panel.
7. Install the secondary riser cage:
a. Align the arrows on the riser cage with the arrows on the power supply cage (callout 1).
b. Press the riser cage down to sit it firmly in the slot (callout 1).
76
Hardware options installation

Table of Contents