EasyManua.ls Logo

HPE ProLiant DL325 Gen10 Plus

HPE ProLiant DL325 Gen10 Plus
149 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Drive cage options
Installing a 2SFF SAS/SATA, NVMe, or uFF drive cage
NOTE: This drive cage assembly can be installed in outer cage only.
Prerequisites
Before you perform this procedure, make sure that you have a T-10 Torx screwdriver available.
Procedure
1. If installed, remove the bezel.
2.
Power down the server.
3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4.
Disconnect all peripheral cables from the server.
5.
Remove the server from the rack.
6.
Remove the inner rack rails.
7.
Remove the access panel.
8.
Remove the outer drive cage.
9.
Remove the media bay blank.
10.
Install the 2SFF drive cage assembly.
11. Remove the cable guard:
a. Remove the screws.
b. Slide the cable guard horizontally to disengage it from the chassis.
c. Remove the cable guard.
Hardware options installation
71

Table of Contents

Other manuals for HPE ProLiant DL325 Gen10 Plus

Related product manuals