4. Disconnect all peripheral cables from the server.
5. Remove the server from the rack.
6. Remove the access panel.
7. Install the DIMM:
a. Open the DIMM slot latches.
b. Align the notch on the bottom edge of the DIMM with the keyed surface of the DIMM slot, and then fully press
the DIMM into the slot until the latches snap back into place.
The DIMM slots are structured to ensure proper installation. If you try to insert a DIMM but it does not fit easily
into the slot, you might have positioned it incorrectly. Reverse the orientation of the DIMM and insert it again.
8.
Install the access panel.
9.
Install the server into the rack.
10.
Connect all peripheral cables to the server.
11.
Connect each power cord to the server.
12.
Connect each power cord to the power source.
13.
Power up the server.
14. If removed, install the bezel.
The installation is complete.
After installing the DIMMs, use the System Utilities > System Configuration > BIOS/Platform Configuration (RBSU) >
Memory Options to configure the memory settings.
Installing the chassis intrusion detection switch
Procedure
1. If installed,
remove the bezel.
2. Power down the server.
Hardware options installation
101