EasyManua.ls Logo

HPE ProLiant DL325 Gen11 - Troubleshooting, Battery, and Specifications; Troubleshooting and System Battery

HPE ProLiant DL325 Gen11
298 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
The embedded video controller in the iLO 6 chipset does not support dual display or screen extension mode. To enable dual display
mode, install a compatible PCIe5 graphics card that supports this feature in the slot 1 in the primary riser.
Rear panel LEDsRear panel LEDs
ItemItem LEDLED StatusStatus DefinitionDefinition
1 Power supply Solid green The power supply is operating normally.
Off One or more of the following conditions exists:
Power is unavailable
Power supply failure
Power supply is in standby mode
Power supply error
2 iLO link Solid green Network link
Off No network link
3 iLO status Solid green Linked to network
Flashing green Network active
Off No network activity
4 UID Solid blue Activated
Flashing blue
1 flash per sec—Remote management or firmware upgrade
in progress
4 flashes per sec—iLO manual reboot sequence initiated
8 flashes per sec—iLO manual reboot sequence in progress
Off Deactivated
System board componentsSystem board components
The grayed out components in the system board image are not for use in this server.