Table 5-2 describes the procedure for configuring the server.
Table 5-2 Procedure for configuring the server
Step Description
Check the server.
l Check the board versions.
l Check for and clear server alarms.
Configure RAID. Configure RAID for the server based on site
requirements.
NOTE
The 5288 V3 supports the following RAID controller cards:
SR120 (LSI SAS2308), SR130 (LSI SAS3008), SR430C (1
GB/2 GB, LSI SAS3108), SR630C (1 GB/2 GB, LSI SAS3108),
and SP435 (PM8060)
Configure the basic input/
output system (BIOS).
Configure the server BIOS, including the boot mode,
network drive, preboot execution environment (PXE)
options of the network interface card (flexible NIC), and
BIOS password.
Change the user password for
iBMC.
Change the default password for iBMC.
Install an operating system
(OS).
For details, see HUAWEI Server OS Installation Guide.
5.3 Checking the 5288 V3
Log in to the iBMC WebUI or CLI to check the health status of the 5288 V3. Ensure that its
health status meets the environment requirements for software installation.
Table 5-3 describes the default information for logging in to the 5288 V3 iBMC WebUI or
CLI. For details about the CLI, see HUAWEI Rack Server iBMC UserGuide.
Table 5-3 Default information
Item
Parameter Default Value
iBMC management
network port
information
IP address and subnet
mask of the
management network
port
l IP address: 192.168.2.100
l Subnet mask: 255.255.255.0
iBMC management
system login
information
User name and
password
l User name: root
l Password: Huawei12#$
5288 V3 Server
User Guide
5 Configuring the 5288 V3
Issue 26 (2018-11-19) Copyright © Huawei Technologies Co., Ltd. 95