Figure 7-28 Installing the supercapacitor tray
Step 6 Install the chassis cover. For details, see 7.12 Installing the Chassis Cover.
Step 7 Install the 5288 V3. For details, see 3.4 Installing the Server.
Step 8 Connect all internal cables such as power and network cables. For details, see 3.5 Connecting
External Cables.
Step 9 Power on the 5288 V3. For details, see 4.1 Powering On the Server.
----End
7.15 Removing a Fan Module
Remove a fan module before replacing it with a new one or removing other components (such
as the mainboard and DVD drive).
Procedure
Step 1 Wear an ESD wrist strap. For details, see 1 Safety Instructions.
Step 2 Determine the rack number and chassis number of the server to be removed, and label its
panel to prevent misoperations.
NOTE
The fan modules are hot-swappable. You can skip steps Step 3 to Step 5 when you can open the chassis
cover without removing the server. The scenarios include but are not limited to: (1) the server is installed
on holding or adjustable guide rails and (2) the server is not installed in a cabinet.
Step 3 Power off the 5288 V3. For details, see 4.2 Powering Off the Server.
5288 V3 Server
User Guide