l Configuring IP addresses for interfaces to ensure that neighboring switches are reachable
at the network layer
l Configuring Basic OSPF Functions
Data Preparation
To configure a stub area, you need the following data.
No. Data
1 (Optional) Cost of the default route to the stub area
NOTE
By default, the cost of the default route to the stub area is 1.
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
ospf [ process-id ]
The OSPF process view is displayed.
Step 3 Run:
area area-id
The OSPF area view is displayed.
Step 4 Run:
stub
The specified area is configured as a stub area.
NOTE
l All switches in a stub area must be configured with stub attributes using the stub command.
l Configuring or deleting stub attributes will update routing information in the area. Stub attributes can
be deleted or configured again only after the routing update is complete.
Step 5 (Optional) Run:
stub [ no-summary ]
The ABR is prevented from sending Type 3 LSAs to the stub area.
Step 6 (Optional) Run:
default-cost cost
The cost of the default route to the stub area is set.
To ensure the reachability of AS external routes, the ABR in the stub area generates a default
route and advertises the route to the non-ABR switches in the stub area.
S6700 Series Ethernet Switches
Configuration Guide - IP Routing 4 OSPF Configuration
Issue 01 (2012-03-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
117

Table of Contents

Other manuals for Huawei S1720 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei S1720 Series and is the answer not in the manual?

Huawei S1720 Series Specifications

General IconGeneral
Operating Humidity5% to 95% (non-condensing)
Uplink Ports4 x GE combo ports
VLANs4094
Power SupplyAC 100-240V, 50/60Hz
Layer 2 FeaturesVLAN
Layer 3 FeaturesStatic routing
ManagementSNMP
Operating Temperature0°C to 45°C
Storage Temperature-40°C to +70°C
Dimensions (W x D x H)442 mm x 220 mm x 43.6 mm