Pre-configuration Tasks
Before configuring the switch to control the receiving of RIPng routing information, complete
the following tasks:
l Configuring IPv6 addresses for interfaces to ensure that neighboring nodes are reachable
at the network layer
l Configuring Basic RIPng Functions
Data Preparation
To control the receiving of RIPng routing information, you need the following data.
No. Data
1 ACL used to filter routing information
3.6.2 Configuring RIPng to Filter the Received Routes
By configure an IPv6 ACL or an IPv6 prefix list to filter received routes, you can configure a
router to selectively receive routes.
Context
Do as follows on the RIPng switch:
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
ripng [ process-id ]
The RIPng view is displayed.
Step 3 Run:
filter-policy { acl6-number | acl6-name acl6-name | ipv6-prefix ipv6-prefix-name }
import
The imported routes are filtered.
You can specify an IPv6 ACL or an IPv6 prefix list to filter the imported routes. Only the routes
that pass the filtering can be added to the RIPng routing table.
----End
3.6.3 Checking the Configuration
After the function of controlling the receiving of RIPng routing information is successfully
configured, you can view RIPng routing information.
S6700 Series Ethernet Switches
Configuration Guide - IP Routing 3 RIPng Configuration
Issue 01 (2012-03-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
71

Table of Contents

Other manuals for Huawei S1720 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei S1720 Series and is the answer not in the manual?

Huawei S1720 Series Specifications

General IconGeneral
Operating Humidity5% to 95% (non-condensing)
Uplink Ports4 x GE combo ports
VLANs4094
Power SupplyAC 100-240V, 50/60Hz
Layer 2 FeaturesVLAN
Layer 3 FeaturesStatic routing
ManagementSNMP
Operating Temperature0°C to 45°C
Storage Temperature-40°C to +70°C
Dimensions (W x D x H)442 mm x 220 mm x 43.6 mm

Related product manuals