No. Data
1 OSPF process ID
4.12.2 Configuring OSPF MIB Binding
The MIB is a virtual database of the device status maintained by the managed devices.
Context
When multiple OSPF processes are enabled, you can configure OSPF MIB to select the process
to be processed, that is, configure OSPF MIB to select the process to which it is bound.
Do as follows on the OSPF router:
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
ospf mib-binding process-id
OSPF MIB binding is configured.
----End
4.12.3 Configuring OSPF Trap
Traps are the notifications sent from a router to inform the NMS of the fault detected by the
system.
Context
Do as follows on the OSPF router.
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
snmp-agent trap enable feature-name ospf { non-excessive all | trap-name
{ ospfifauthfailure | ospfifconfigerror | ospfifrxbadpacket | ospfifstatechange |
ospflsdbapproachingoverflow | ospflsdboverflow | ospfmaxagelsa |
ospfnbrrestarthelperstatuschange | ospfnbrstatechange |
ospfnssatranslatorstatuschange | ospforiginatelsa | ospfrestartstatuschange |
ospftxretransmit | ospfvirtifauthfailure | ospfvirtifconfigerror |
ospfvirtifrxbadpacket | ospfvirtifstatechange | ospfvirtiftxretransmit |
ospfvirtnbrrestarthelperstatuschange | ospfvirtnbrstatechange } }
S6700 Series Ethernet Switches
Configuration Guide - IP Routing 4 OSPF Configuration
Issue 01 (2012-03-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
133

Table of Contents

Other manuals for Huawei S1720 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei S1720 Series and is the answer not in the manual?

Huawei S1720 Series Specifications

General IconGeneral
Operating Humidity5% to 95% (non-condensing)
Uplink Ports4 x GE combo ports
VLANs4094
Power SupplyAC 100-240V, 50/60Hz
Layer 2 FeaturesVLAN
Layer 3 FeaturesStatic routing
ManagementSNMP
Operating Temperature0°C to 45°C
Storage Temperature-40°C to +70°C
Dimensions (W x D x H)442 mm x 220 mm x 43.6 mm

Related product manuals