2. Run:
bgp as-number
The BGP view is displayed.
3. Run:
timer connect-retry connect-retry-time
A BGP4+ ConnectRetry interval is set globally.
By default, the ConnectRetry interval is 32s.
l Set a ConnectRetry interval on a peer or peer group.
Do as follows on the BGP4+ switch:
1. Run:
system-view
The system view is displayed.
2. Run:
bgp as-number
The BGP view is displayed.
3. Run:
peer { group-name | ipv6-address } timer connect-retry connect-retry-time
A ConnectRetry interval is set on a peer or peer group.
By default, the ConnectRetry interval is 32s.
The ConnectRetry interval configured on a peer or peer group takes precedence over
a global ConnectRetry interval.
----End
8.6.4 Checking the Configuration
After parameters of a connection between BGP4+ peers are configured, you can check BGP4+
peers and peer groups.
Prerequisites
The configurations for parameters of a connection between BGP4+ peers are complete.
Procedure
l Run the display bgp ipv6 peer ipv4-address verbose command to check detailed
information about the BGP4+ peers.
l Run the display bgp ipv6 peer ipv6-address { log-info | verbose } command to check
information about the BGP4+ peers.
----End
8.7 Configuring BGP4+ Tracking
On a network where BFD is unsuitable to deploy, you can configure BGP4+ tracking to
implement the fast convergence of IBGP routes.
S6700 Series Ethernet Switches
Configuration Guide - IP Routing 8 BGP4+ Configuration
Issue 01 (2012-03-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
522

Table of Contents

Other manuals for Huawei S1720 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei S1720 Series and is the answer not in the manual?

Huawei S1720 Series Specifications

General IconGeneral
Operating Humidity5% to 95% (non-condensing)
Uplink Ports4 x GE combo ports
VLANs4094
Power SupplyAC 100-240V, 50/60Hz
Layer 2 FeaturesVLAN
Layer 3 FeaturesStatic routing
ManagementSNMP
Operating Temperature0°C to 45°C
Storage Temperature-40°C to +70°C
Dimensions (W x D x H)442 mm x 220 mm x 43.6 mm

Related product manuals