Procedure
l Run the display ipv6 routing-table command to check brief information about the IPv6
routing table.
l Run the display ipv6 routing-table verbose command to check detailed information about
the IPv6 routing table.
----End
1.5 Configuring BFD for IPv4 Static Routes on the Public
Network
On an IPv4 network, configuring BFD for IPv4 static routes on the public network can speed
up route convergence and improve network reliability.
1.5.1 Establishing the Configuration Task
Before configuring BFD for static routes, familiarize yourself with the applicable environment,
complete the pre-configuration tasks, and obtain the data required for the configuration. This
will help you complete the configuration task quickly and accurately.
Applicable Environment
BFD can quickly detect IPv4 forwarding failures, ensuring QoS for voice, video, and other video-
on-demand (VoD) services on an IPv4 network. With BFD, service providers can provide voice
over IP (VoIP) and other real-time services with high availability and scalability.
By binding IPv4 static routes to BFD sessions, you can use BFD sessions to provide link
detection for IPv4 static routes on the public network. A static route can be bound to a BFD
session.
Pre-configuration Tasks
Before configuring BFD for IPv4 static routes on the public network, complete the following
task:
l Configuring link layer protocol parameters and IP addresses for interfaces to ensure that
the link layer protocol status of the interfaces is Up
Data Preparation
To configure BFD for IPv4 static routes on the public network, you need the following data.
No.
Data
1 Destination address and mask
2 Outbound interface or next-hop IPv4 address
3 IP address of the peer detected by BFD
4 Local discriminator and remote discriminator of a BFD session
S6700 Series Ethernet Switches
Configuration Guide - IP Routing 1 IP Static Route Configuration
Issue 01 (2012-03-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
8

Table of Contents

Other manuals for Huawei S1720 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei S1720 Series and is the answer not in the manual?

Huawei S1720 Series Specifications

General IconGeneral
Operating Humidity5% to 95% (non-condensing)
Uplink Ports4 x GE combo ports
VLANs4094
Power SupplyAC 100-240V, 50/60Hz
Layer 2 FeaturesVLAN
Layer 3 FeaturesStatic routing
ManagementSNMP
Operating Temperature0°C to 45°C
Storage Temperature-40°C to +70°C
Dimensions (W x D x H)442 mm x 220 mm x 43.6 mm