EasyManua.ls Logo

Huawei SmartAX MA5608T - H801 SPUB Board Description

Huawei SmartAX MA5608T
977 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Indicator
Indicato
r
Name Color Status Meaning
RUN
ALM
Running
status
indicator
Red Blinking The board enters the APP
start phase during the
board startup
Green Blinking quickly (on
for 0.25 s and off for
0.25 s repeatedly)
The board enters the phase
of communication with the
control board during its
startup
Green Blinking slowly (on
for 1 s and off for 1 s
repeatedly)
The board works in the
normal state
Orange Blinking A high-temperature alarm
is generated
Red On The board is faulty
ACT Active
indicator
Green On This board is active
Yellow On This board works in the
load-balancing mode
- Off This board is standby
LINK Link status
indicator
Green On A connection is set up on
the port
- Off No connection is set up on
the port
ACT Data status
indicator
Yellow Blinking Data is being transmitted
- Off No data is being
transmitted
3.12.3 H801SPUB Board Description
The H801SPUB board is a MPLS service processing unit board.
Functional Specifications
l 10 Gbit/s MPLS switching capability
– Unidirectional 10 Gbit/s, bidirectional 5 Gbit/s when only one control board
(SCUx) is working
– Bidirectional 10 Gbit/s when two control boards (SCUx) are working in load
sharing mode (V800R011C00 and later versions)
l Active/standby switchover of the control boards
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Hardware Description
3 Board
Issue 24 (2018-07-30) Huawei Proprietary and Confidential