Working Principle
Figure 3-128 Working principle of the H806VCPE board
Power
module
Voltage required
by the board
-48V
DC
power
Clock
module
Clock required
by the board
Backplane
Control
board
B
a
c
k
p
l
a
n
e
C
o
n
n
e
c
t
o
r
Control module
Interface
module
Framer
module
Forwarding
module
Service
signal
Control
signal
Power
signal
Clock
signal
DC
block
Protector
Protection
module
SPL module
VTU-R
PSTNPSTN0
LINE1
LINE0
PSTN1
H806VCPE
GE/
10GE
10GE
Front Panel
The basic working principle of the H806VCPE board is as follows:
l The control module loads the board software, controls the running of the board, and
manages the board.
l The protection module protects and isolates the board from lightning strikes. The DC
block isolates the direct current. The protector protects the high voltage.
l The splitter module separates POTS signals from VDSL2 signals over the subscriber
line.
l The interface module provides two functions:
In the upstream direction, the interface module converts line signals into cell flows,
aggregates the cell flows to the forwarding module, and then reassembles the cell
flows into ATM/PTM packets.
In the downstream direction, the interface module converts the ATM/PTM cell
flows sent from the forwarding module into line signals that are transmitted
downstream.
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Hardware Description
3 Board
Issue 24 (2018-07-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
669

Table of Contents

Other manuals for Huawei SmartAX MA5608T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei SmartAX MA5608T and is the answer not in the manual?

Huawei SmartAX MA5608T Specifications

General IconGeneral
Dual Power SupplyYes
Humidity5% to 95% (non-condensing)
Uplink Slots2
Maximum GPON Ports16
Input Voltage Range-38.4 V DC to -72 V DC
Device TypeOLT
Power Supply-48 V DC
Operating Temperature-25°C to +55°C
Storage Temperature-40°C to 70°C
Switching Capacity128 Gbps
PortsGPON, XG-PON, 10GE