EasyManua.ls Logo

Hypertherm XPR170 - Page 91

Hypertherm XPR170
176 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Gas Connect Consoles
2
XPR170 Field Service Bulletin 810410 91
5. Push-to-connect the mixed-fuel gas line to the outlet-side
of the mixer module. This connection is easier to make if done
before regulator installation. Refer to How to use
push-to-connect fittings on page 68.
6. Put the regulator on top of the manifold. Make sure that the
regulators-bracket assembly is correctly installed:
The 2 slots on the bracket are near the output-side of the
gas connect console.
The regulator fitting that has the 90-degree angle is
behind the gas connect console.
7. Use an 8 mm nut driver or socket wrench to install the
2 nuts on the 2 swage-nut studs on the mixer module.
8. Use a #2 Phillips screwdriver to install the 2 screws on
the bracket . Do not fully tighten the screws.
9. Put the mixer module bracket-assembly on the manifold.
Adjust the mixer module bracket-assembly as necessary
for good alignment. It can be necessary to loosen the
2 screws on the inlet-side to make adjustments.
10. Tighten the 2 screws on the bracket.
11 . Push-to-connect the N
2
and Ar gas lines in the
outlet-side of the gas regulators. Refer to How to use
push-to-connect fittings on page 68.
3
3
5
4
4
5
4
5
6
7
6
7

Table of Contents