Gas Connect Consoles
2
92 810410 Field Service Bulletin XPR170
12. Push-to-connect the N
2
and Ar gas lines in the
inlet-side of the gas regulators. Refer to How to use
push-to-connect fittings on page 68.
13. Push-to-connect the air-gas line . Refer to How to use
push-to-connect fittings on page 68.
14. Make sure that all push-to-connect fittings are correctly
installed. A connection is good if you cannot see the
silver ring around the gas line.
15. Connect the SV100 connector to the mixer module.
8
9
8
9
10
10
11
11