8. Parameter
Fieldbus Communication
186
RCP6
S
8.1 Parameter List
The categories in the table below indicate whether parameters should be set or not. There are
five categories as follows:
A : Check the settings before use.
B : Use parameters of this category depending on their uses.
C : Use parameters of this category with the settings at shipments leaving unchanged as a
rule. Normally they may not be set.
D : Parameters of the category are set at shipment in accordance with the specification of
the actuator. Normally they may not be set.
E : Parameters of the category are exclusively used by us for convenience of production.
Changing their settings may not only cause the actuator to operate improperly but also to
be damaged. So, never change the setting of the parameters.
Category do not appear on the teaching tool.
Also, the unused parameter numbers are not mentioned in the list.
Parameter List (1/5)
Applicable
Controller
(Note 3)
No.
Category
Name Symbol Unit
(Note 1)
Input Range
Default factory
setting
A P D
Relevant
sections
1 B
Zone Boundary 1 Positive
Side
ZONM
mm
[deg]
-9999.99 to
9999.99
Actual stroke on
positive side
(Note 2)
2 B
Zone Boundary 1 Negative
Side
ZONL
mm
[deg]
-9999.99 to
9999.99
Actual stroke on
negative side
(Note 2)
8.2 [1]
3 A Soft Limit Positive Side LIMM
mm
[deg]
-9999.99 to
9999.99
Actual stroke on
positive side
(Note 2)
4 A Soft Limit Negative Side LIML
mm
[deg]
-9999.99 to
9999.99
Actual stroke on
negative side
(Note 2)
8.2 [2]
5 D Home Return Direction ORG -
0: Reverse
1: Normal
In accordance with
actuator
(Note 2)
8.2 [3]
6 C
Push & Hold Stop Judgment
Period
PSWT msec 0 to 9999
In accordance with
actuator
(Note 2)
8.2 [4]
7 C Servo Gain Number PLGO - 0 to 31
In accordance with
actuator
(Note 2)
8.2 [5]
8.3
8 B Default Velocity VCMD
mm/s
[deg/s]
1 to Actuator’s max.
speed
Rated actuator
speed
(Note 2)
8.2 [6]
9 B
Default
Acceleration/Deceleration
ACMD G
0.01 to Actuator's
max. acceleration/
deceleration
Rated actuator's
acceleration/
Deceleration
(Note 2)
8.2 [7]
10 B Default Positioning Width INP
mm
[deg]
Actuator's min.
resolution to 999.99
In accordance with
actuator
(Note 2)
8.2 [8]
12 B
Current limitation at
positioning stop
SPOW % 0 to 70
In accordance with
actuator
(Note 2)
-
- 8.2 [9]
0 to 100 - -
13 C
Current-Limiting Value During
Home Return
ODPW %
0 to 300
In accordance with
actuator
(Note 2)
-
8.2 [10]
16 B
SIO Communication Speed
Selection
BRSL dps 9600 to 230400 38400 8.2 [11]
17 B
Minimum Delay Time for
Slave Transmitter Activation
RTIM msec 0 to 255 5 8.2 [12]
18 E
Home Position Check Sensor
Input Polarity
LS - 0 to 2
In accordance
with actuator
(Note 2)
- 8.2 [13]
22 C Home Return Offset Level OFST
mm
[deg]
0.00 to 9999.99
In accordance
with actuator
(Note 2)
8.2 [14]
23 B
Zone Boundary 2 Positive
Side
ZNM2
mm
[deg]
-9999.99 to
9999.99
Actual stroke on
positive side
(Note 2)
24 B
Zone Boundary 2 Negative
Side
ZNL2
mm
[deg]
-9999.99 to
9999.99
Actual stroke on
negative side
(Note 2)
8.2 [15]
8.2 [1]
Note 1 The unit [deg] is for rotary actuator and lever type gripper. It is displayed in [mm] in the teaching tools.
Note 2 The setting values vary in accordance with the specification of the actuator. At shipment, the
parameters are set in accordance with the specification.
Note 3
A: RCM-P6AC, P: RCP6S and RCM-P6PC, D: RCM-P6DC
ME0349-4B

Table of Contents

Other manuals for IAI RCP6S

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IAI RCP6S and is the answer not in the manual?

IAI RCP6S Specifications

General IconGeneral
BrandIAI
ModelRCP6S
CategoryConference System
LanguageEnglish

Related product manuals