IBM pSeries 630 6C4 - MAP 1522: Cannot Power On the I;O Drawer, Power Present LED Does Not Come On

IBM pSeries 630 6C4
651 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Step 1321-26
If you performed substep 3 of “Step 1321-24” on page 90 for the current Linux partition, go to “Step
1321-27”, and when asked in “Step 1321-27”, do not record any RTAS messages from “Step 1321-26” for
the current Linux partition.
Examine the Linux boot (IPL) log by logging in to the system as the root user and entering the following
command:
cat /var/log/boot.msg |grep RTAS |more
Linux boot (IPL) error messages are logged into the boot.msg file under /var/log. The following is an
example of the Linux boot error log.
RTAS daemon started
RTAS: -------- event-scan begin --------
RTAS: Location Code: U0.1-F3
RTAS: WARNING: (FULLY RECOVERED) type: SENSOR
RTAS: initiator: UNKNOWN target: UNKNOWN
RTAS: Status: bypassed new
RTAS: Date/Time: 20020830 14404000
RTAS: Environment and Power Warning
RTAS: EPOW Sensor Value: 0x00000001
RTAS: EPOW caused by fan failure
RTAS: -------- event-scan end ----------
Step 1321-27
Record any RTAS messages found in the Linux boot (IPL) log in Step 1321-26. Ignore all other messages
in the Linux boot (IPL) log. If the system is configured with more than one logical partition with Linux
installed, repeat “Step 1321-26” and “Step 1321-27” for all logical partitions that have Linux installed.
94 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide