SPCN Error Codes
Attention: If a power supply or fan is hot-swapped, wait five minutes, then recheck the operating system
error log. If the system has to be shut down to replace a power supply or fan, reboot the system, wait five
minutes after the operating system login prompt appears, then recheck the operating system error log. If
the detailed information for the most recent error with the same identifier indicates that the original problem
has not been fixed by performing the first action in the action column, continue with the next action in the
action column.
Attention: If you replace FRUs or perform an action and the problem is still not corrected, go to “MAP
1548: Processor Subsystem Problem Isolation” on page 139 unless otherwise indicated in the tables.
If you replace FRUs and the problem is corrected, go to MAP 0410: Repair Checkout in the RS/6000
Eserver pSeries Diagnostic Information for Multiple Bus Systems.
Table 2. SPCN Error Codes for the CEC (system unit)
Error Code Description Action/
Possible Failing FRU
1011 00AC AC loss or brownout detected Informational
1011 00EF Room emergency power off detected Informational
1011 1510 Power supply 1 power source failure
1. Check input power to the power supply
2. System power supply 1
Location: U0.1-V1
3. CEC backplane
Location: U0.1-P1
1011 1511 Power supply 1 fault
1. Verify that the media support shelf is installed
and properly seated.
2. System power supply 1
Location: U0.1-V1
3. CEC backplane
Location: U0.1-P1
1011 1512 Power supply 1 non-power fault
1. System power supply 1
Location: U0.1-V1
2. CEC backplane
Location: U0.1-P1
1011 1513 Power supply 1 domain fault
1. Verify that the media support shelf is installed
and properly seated.
2. System power supply 1
Location: U0.1-V1
3. CEC backplane
Location: U0.1-P1
1011 1520 Power supply 2 power source failure
1. Check input power to power supply 2
2. System power supply 2
Location: U0.1-V2
3. CEC backplane
Location: U0.1-P1
1011 1521 Power supply 2 fault
1. System power supply 2
Location: U0.1-V2
2. CEC backplane
Location: U0.1-P1
Chapter 5. Error Code to FRU Index 217

Table of Contents

Other manuals for IBM pSeries 630 6C4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM pSeries 630 6C4 and is the answer not in the manual?

IBM pSeries 630 6C4 Specifications

General IconGeneral
BrandIBM
ModelpSeries 630 6C4
CategoryServer
LanguageEnglish

Related product manuals