Table 2. SPCN Error Codes for the CEC (system unit) (continued)
Error Code Description Action/
Possible Failing FRU
1011 1522 Power supply 2 non-power fault
1. System power supply 2
Location: U0.1-V2
2. CEC backplane
Location: U0.1-P1
1011 1523 Power supply 2 domain fault
1. System power supply 2
Location: U0.1-V2
2. CEC backplane
Location: U0.1-P1
1011 1B0A +12V/-12V load fault
1. Replace power supply 1
Location: U0.1-V1
2. If power supply 2 is present, use removed
power supply 1 to replace power supply 2
3. CEC backplane
Location: U0.1-P1
1011 1B0B 1.8V load fault
1. Replace power supply 1
Location: U0.1-V1
2. If power supply 2 is present, use removed
power supply 1 to replace power supply 2
3. CEC backplane
Location: U0.1-P1
1011 1B0C 3.3V/1.5V load fault
1. Replace power supply 1
Location: U0.1-V1
2. If power supply 2 is present, use removed
power supply 1 to replace power supply 2
3. CEC backplane
Location: U0.1-P1
1011 1B0D 2.5V load fault
1. Replace power supply 1
Location: U0.1-V1
2. If power supply 2 is present, use removed
power supply 1 to replace power supply 2
3. CEC backplane
Location: U0.1-P1
1011 1B0E +5V load fault
1. Replace power supply 1
Location: U0.1-V1
2. If power supply 2 is present, use removed
power supply 1 to replace power supply 2
3. CEC backplane
Location: U0.1-P1
1011 1B0F 1.5V/1.3V load fault
1. Replace power supply 1
Location: U0.1-V1
2. If power supply 2 is present, use removed
power supply 1 to replace power supply 2
3. CEC backplane
Location: U0.1-P1
1011 1F01 TMS log limit reached Call service support.