Problem Determination Generated Error Codes
Table 6. Problem Determination Generated Error Codes
Error Code Description Action/
Possible Failing FRU
M0BT 0000 The system hung during speaker POST. This
error code is generated by the customer
performing “Problem Determination” in the
Eserver pSeries 630 Model 6C4 and Model
6E4 User’s Guide.
Go to “MAP 1540: Problem Isolation Procedures”
on page 124.
M0BT 0001 The system hung during “Starting Software...”.
This error code is generated by the customer
performing “Problem Determination” in the
Eserver pSeries 630 Model 6C4 and Model
6E4 User’s Guide.
Go to “MAP 1540: Problem Isolation Procedures”
on page 124.
M0KB D000 The system hung during keyboard POST. This
error code is generated by the customer
performing “Problem Determination” in the
Eserver pSeries 630 Model 6C4 and Model
6E4 User’s Guide.
1. Keyboard
2. CEC backplane
Location: U0.1-P1
M0KB D001 The system did not respond to a keyboard entry.
This error code is generated by the customer
performing “Problem Determination” in the
Eserver pSeries 630 Model 6C4 and Model
6E4 User’s Guide.
Type 101 keyboard
1. Keyboard
2. CEC backplane
Location: U0.1-P1
M0KB D002 The system did not respond to a keyboard entry.
This error code is generated by the customer
performing “Problem Determination” in the
Eserver pSeries 630 Model 6C4 and Model
6E4 User’s Guide.
Type 102 keyboard
1. Keyboard
2. CEC backplane
Location: U0.1-P1
M0KB D003 The system did not respond to a keyboard entry.
This error code is generated by the customer
performing “Problem Determination” in the
Eserver pSeries 630 Model 6C4 and Model
6E4 User’s Guide.
1. Keyboard
2. CEC backplane
Location: U0.1-P1
M0ME M002 The system hung during memory POST. This
error code is generated by the customer
performing “Problem Determination” in the
Eserver pSeries 630 Model 6C4 and Model
6E4 User’s Guide.
Go to “MAP 1540: Problem Isolation Procedures”
on page 124.
M0NE T000 The system hung during network POST. This
error code is generated by the customer
performing “Problem Determination” in the
Eserver pSeries 630 Model 6C4 and Model
6E4 User’s Guide.
Go to “MAP 1540: Problem Isolation Procedures”
on page 124.
M0PS 0000 Power failure. This error code is generated by
the customer performing “Problem
Determination” in the Eserver pSeries 630
Model 6C4 and Model 6E4 User’s Guide.
Go to “MAP 1520: Power” on page 105.
M0SC SI00 Unable to load diagnostics. This error code is
generated by the customer performing “Problem
Determination” in the Eserver pSeries 630
Model 6C4 and Model 6E4 User’s Guide.
Go to “Boot Problems/Concerns” on page 204.
Chapter 5. Error Code to FRU Index 351