Table 2. SPCN Error Codes for the CEC (system unit) (continued)
Error Code Description Action/
Possible Failing FRU
1011 2600 Pgood fault CEC backplane
Location: U0.1-P1
1011 2603 Pgood fault CEC backplane
Location: U0.1-P1
1011 2612 Optical converter fault CEC backplane
Location: U0.1-P1
1011 3100 I2C controller fault CEC backplane
Location: U0.1-P1
1011 3104 VPD collection problem with SES devices
1. DASD backplane
Location: U0.1-P3
2. PCI riser
Location: U0.1-P2.
3. System backplane
Location: U0.1-P1
1011 3105 I2C port 5 fault CEC backplane
Location: U0.1-P1
1011 3114 PCI riser card fault
1. PCI riser card
Location: U0.1-P2
2. CEC backplane
Location: U0.1-P1
1011 3116 I
2
C VPD interface CEC backplane
Location: U0.1-P1
1011 3118 SPCN VPD and NVS interface CEC backplane
Location: U0.1-P1
1011 3119 VPD collection problem with DASD backplane DASD backplane
Location: U0.1-P3
1011 311E VPD collection problem with PCI riser PCI riser card
Location: U0.1-P2
1011 7610 System processor fan 1 failure
1. Processor fan 1
Location: U0.1-F1
2. CEC backplane
Location: U0.1-P1
1011 7611 Processor card cooling fan missing from primary
location
1. Processor fan 1
Location: U0.1-F1
2. CEC backplane
Location: U0.1-P1
1011 7620 System processor fan 2 failure
1. Processor fan 2
Location: U0.1-F2
2. CEC backplane
Location: U0.1-P1
1011 7621 System processor fan 2 missing
1. Processor fan 2
Location: U0.1-F2
2. CEC backplane
Location: U0.1-P1
Chapter 5. Error Code to FRU Index 219