Checkpoint Description Action/
Possible Failing FRU
8009 Set NVRAM configuration in TITAN See note 1 on page 167.
800F Start base code See note 1 on page 167.
8010 Start supervisor in base code See note 1 on page 167.
8012 Initialize hardware interrupts See note 1 on page 167.
8014 Allocate and initialize area in DRAM See note 1 on page 167.
8016 Initialize debugger and build VPD See note 1 on page 167.
8018 Initialize service processor interfaces See note 1 on page 167.
801A Initialize external FLASH load See note 1 on page 167.
801B Initialize and test ISA hub chip See note 1 on page 167.
801C Initialize and test SUPER I/O chip See note 1 on page 167.
801F Initialize diskette, verify VDASD and start
operational loader
See note 1 on page 167.
809x Related to recovery mode system firmware
update from diskette
See note 3 on page 167.
8092 Diskette initialization during recovery mode
system firmware update
See note 3 on page 167.
8098 Firmware image being read during recovery
mode system firmware update
See note 3 on page 167.
809C Firmware image being written during
recovery mode system firmware update
See note 3 on page 167.
809F Diskette error during recovery mode system
firmware update
See note 3 on page 167.
8100 Start operational loader See note 1 on page 167.
81xx Load code into DRAM from VDASD (where
xx = number of loads)
See note 1 on page 167.
81FE Load service processor operating system See note 1 on page 167.
81FF Start service processor operating system See note 1 on page 167.
9000 Primary service processor task initializing See note 1 on page 167.
9009 System processor IPL has started See note 1 on page 167.
9010 Primary service processor thread waiting
for response
See note 1 on page 167.
9020 Service processor state set to pre-standby See note 1 on page 167.
9021 Service processor state set to standby See note 1 on page 167.
9022 Service processor state set to IPL See note 1 on page 167.
9023 Service processor state set to runtime See note 1 on page 167.
9024 Service processor state set to terminate See note 1 on page 167.
9025 Service processor state set to DPO See note 1 on page 167.
9030 Waiting for secondary thread
acknowledgement
See note 1 on page 167.
9033 I/O base initialization See note 1 on page 167.
9034 I2C initialization See note 1 on page 167.
9035 ISA initialization See note 1 on page 167.
9036 Mailbox initialization See note1 on page 167.
162 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide

Table of Contents

Other manuals for IBM pSeries 630 6C4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM pSeries 630 6C4 and is the answer not in the manual?

IBM pSeries 630 6C4 Specifications

General IconGeneral
BrandIBM
ModelpSeries 630 6C4
CategoryServer
LanguageEnglish

Related product manuals