EasyManua.ls Logo

IBM pSeries 630 6C4 - Page 200

IBM pSeries 630 6C4
651 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Checkpoint Description Action/
Possible Failing FRU
E532 RIO cable detected; enable the RIO hub
port
1. Replace the RIO-2 cable specified by
the location code.
2. Replace the RIO riser card that the
failing drawer is attached to.
3. Replace the RIO riser card (location:
U0.dd-P1.1) in the I/O subsystem that
the RIO cable in step 1 is attached to.
4. If the location code associated with this
checkpoint specifies a PCI adapter
card, replace the adapter card.
5. Replace the I/O subsystem planar that
the RIO-2 cable in step 1 is attached to.
6. Go to “MAP 1540: Problem Isolation
Procedures” on page 124.
E533 Set up the RIO hub routing table
1. Replace the RIO-2 cable specified by
the location code.
2. Replace the RIO riser card that the
failing drawer is attached to.
3. Replace the RIO riser card (location:
U0.dd-P1.1) in the I/O subsystem that
the RIO cable in step 1 is attached to.
4. If the location code associated with this
checkpoint specifies a PCI adapter
card, replace the adapter card.
5. Replace the I/O subsystem planar that
the RIO-2 cable in step 1 is attached to.
6. Go to “MAP 1540: Problem Isolation
Procedures” on page 124.
E534 Get the node ID of the node on the other
end of the RIO cable
1. This error code may indicate that the
RIO cables are not properly connected
to the I/O subsystems. Check the RIO
cabling.
2. Replace the RIO-2 cable specified by
the location code.
3. Replace the RIO riser card that the
failing drawer is attached to.
4. Replace the RIO riser card (location:
U0.dd-P1.1) in the I/O subsystem that
the RIO cable in step 1 is attached to.
5. If the location code associated with this
checkpoint specifies a PCI adapter
card, replace the adapter card.
6. Replace the I/O subsystem planar that
the RIO-2 cable in step 1 is attached to.
7. Go to “MAP 1540: Problem Isolation
Procedures” on page 124.
180 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide

Table of Contents

Other manuals for IBM pSeries 630 6C4

Related product manuals