Checkpoint Description Action/
Possible Failing FRU
E547 Set up the RIO interface chip routing table
1. Replace the I/O subsystem planar
specified by the location code.
2. Replace the RIO riser card (location:
U0.dd-P1.1) in the I/O subsystem that
the RIO cable in step 1 is attached to.
3. If the location code associated with this
checkpoint specifies a PCI adapter
card, replace the adapter card.
4. Replace the I/O subsystem planar that
the RIO cable in step 1 is attached to.
E548 Disable any node mode
1. Replace the I/O subsystem planar
specified by the location code.
2. Replace the RIO riser card (location:
U0.dd-P1.1) in the I/O subsystem that
the RIO cable in step 1 is attached to.
3. If the location code associated with this
checkpoint specifies a PCI adapter
card, replace the adapter card.
4. Replace the I/O subsystem planar that
the RIO cable in step 1 is attached to.
E549 Adjust RIO hub table
1. Replace the I/O subsystem planar
specified by the location code.
2. Replace the RIO riser card (location:
U0.dd-P1.1) in the I/O subsystem that
the RIO cable in step 1 is attached to.
3. If the location code associated with this
checkpoint specifies a PCI adapter
card, replace the adapter card.
4. Replace the I/O subsystem planar that
the RIO cable in step 1 is attached to.
184 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide