Checkpoint Description Action/
Possible Failing FRU
E570 Initialize the PCI-ISA bridge chip Replace the device specified by the
location code.
If the device specified by the location code
is the RIO riser card in an I/O subsystem
(location: U0.dd-P1.1), and replacing it
does not resolve the problem, replace the
I/O backplane (location: U0.dd-P1) in the
same I/O subsystem.
E571 Initialize the integrated Ethernet (if present) Replace the device specified by the
location code.
If the device specified by the location code
is the RIO riser card in an I/O subsystem
(location: U0.dd-P1.1), and replacing it
does not resolve the problem, replace the
I/O backplane (location: U0.dd-P1) in the
same I/O subsystem.
E572 Initialize the integrated SCSI Replace the device specified by the
location code.
If the device specified by the location code
is the RIO riser card in an I/O subsystem
(location: U0.dd-P1.1), and replacing it
does not resolve the problem, replace the
I/O backplane (location: U0.dd-P1) in the
same I/O subsystem.
E57F End of RIO interface chip initialization
1. Check for system firmware updates.
2. Go to “MAP 1540: Problem Isolation
Procedures” on page 124.
E580 Begin initializing the EADS module.
1. Check for system firmware updates.
2. Replace the I/O subsystem’s RIO riser
card (location: U0.dd-P1.1) specified by
the location code.
3. If the location code associated with this
checkpoint specifies a PCI adapter
card, replace the adapter card.
4. Replace the I/O subsystem backplane
specified by the location code.
5. Go to “MAP 1542: I/O Problem
Isolation” on page 127.