Table 5. Service Processor Error Codes.
Error Code Description Action/
Possible Failing FRU
4064 0001 Scan interface basic assurance tests detected a
CEC backplane fault
CEC backplane
Location: U0.1-P1
4064 0002 CEC backplane fault CEC backplane
Location: U0.1-P1
4064 0003 Scan interface basic assurance tests detected
processor fault
Processor card
Location: U0.1-P1-C1
4064 0004 Processor fault Processor card
Location: U0.1-P1-C2
4064 000E Processor capacity card Operator panel
Location: U0.1-L1
4064 0010 Memory DIMM fault Memory DIMM
Location: U0.1-P1-C1-M8
4064 0011 Memory DIMM fault Memory DIMM
Location: U0.1-P1-C1-M6
4064 0012 Memory DIMM fault Memory DIMM
Location: U0.1-P1-C1-M1
4064 0013 Memory DIMM fault Memory DIMM
Location: U0.1-P1-C1-M3
4064 0014 Memory DIMM fault Memory DIMM
Location: U0.1-P1-C1-M7
4064 0015 Memory DIMM fault Memory DIMM
Location: U0.1-P1-C1-M5
4064 0016 Memory DIMM fault Memory DIMM
Location: U0.1-P1-C1-M2
4064 0017 Memory DIMM fault Memory DIMM
Location: U0.1-P1-C1-M4
4064 0018 Memory DIMM fault Memory DIMM
Location: U0.1-P1-C2-M8
4064 0019 Memory DIMM fault Memory DIMM
Location: U0.1-P1-C2-M6
4064 001A Memory DIMM fault Memory DIMM
Location: U0.1-P1-C2-M1
4064 001B Memory DIMM fault Memory DIMM
Location: U0.1-P1-C2-M3
4064 001C Memory DIMM fault Memory DIMM
Location: U0.1-P1-C2-M7
4064 001D Memory DIMM fault Memory DIMM
Location: U0.1-P1-C2-M5
4064 001E Memory DIMM fault Memory DIMM
Location: U0.1-P1-C2-M2
4064 001F Memory DIMM fault Memory DIMM
Location: U0.1-P1-C2-M4
4064 00B0 Bus controller failure
1. Check for system firmware updates
2. PCI riser card
Location: U0.1-P2
250 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide