EasyManuals Logo

IBM pSeries 630 6C4 User Manual

IBM pSeries 630 6C4
651 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #274 background imageLoading...
Page #274 background image
Table 5. Service Processor Error Codes. (continued)
Error Code Description Action/
Possible Failing FRU
4064 0EB6 Attention line 5 stuck fault Go to “MAP 1540: Problem Isolation Procedures”
on page 124.
4064 0EB7 Attention line 6 stuck fault Go to “MAP 1540: Problem Isolation Procedures”
on page 124.
4064 0EB8 Attention line 7 stuck fault Go to “MAP 1540: Problem Isolation Procedures”
on page 124.
4064 0EB9 Attention line 8 stuck fault Go to “MAP 1540: Problem Isolation Procedures”
on page 124.
4064 0EBA Attention line 9 stuck fault Go to “MAP 1540: Problem Isolation Procedures”
on page 124.
4064 0EBB Attention line 10 stuck fault Go to “MAP 1540: Problem Isolation Procedures”
on page 124.
4064 0EBC Attention line 11 stuck fault Go to “MAP 1540: Problem Isolation Procedures”
on page 124.
4064 0EBF Description: Memory error
Action:
1. Reboot the system in slow mode to the SMS menus. See “Performing Slow Boot” on page 209.
2. Examine the service processor error log.
v If a CEC subsystem error (a 4xxx yyyy error) occurred during the slow boot that calls out the
memory, processors, L3 cache modules or the primary I/O book, replace the part indicated
by the location code.
v If a CEC subsystem error (a 4xxx yyyy error) did not occur during the slow boot, look for a
4xxx yyyy error immediately preceding the 4064 0EBF error. Replace the part indicated by
the location code associated with that error.
4064 0EE1 Service processor firmware: invalid MRU to FRU
mapping
1. Check for system firmware updates.
2. Call service support.
4064 0EE2 Service processor firmware fault
1. Check for system firmware updates.
2. Call service support.
4064 0EE5 Firmware error, no callout available
1. Check for system firmware updates.
2. Call service support.
4065 0001 Scan interface basic assurance tests detected a
CEC backplane fault
CEC backplane
Location: U0.1-P1
4065 0002 CEC backplane fault
1. Check JTAG cable connections
2. CEC backplane
Location: U0.1-P1
4065 0003 Scan interface basic assurance tests detected
processor fault
1. Check JTAG cable connections.
2. Processor card
Location: U0.1-P1-C1
4065 0004 Processor fault
1. Check JTAG cable connections.
2. Processor card
Location: U0.1-P1-C2
4065 000E Processor capacity card Operator Panel
Location: U0.1-L1
254 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide

Table of Contents

Other manuals for IBM pSeries 630 6C4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM pSeries 630 6C4 and is the answer not in the manual?

IBM pSeries 630 6C4 Specifications

General IconGeneral
BrandIBM
ModelpSeries 630 6C4
CategoryServer
LanguageEnglish

Related product manuals