Table 5. Service Processor Error Codes. (continued)
Error Code Description Action/
Possible Failing FRU
4067 0010 Memory DIMM fault Memory DIMM
Location: U0.1-P1-C1-M8
4067 0011 Memory DIMM fault Memory DIMM
Location: U0.1-P1-C1-M6
4067 0012 Memory DIMM fault Memory DIMM
Location: U0.1-P1-C1-M1
4067 0013 Memory DIMM fault Memory DIMM
Location: U0.1-P1-C1-M3
4067 0014 Memory DIMM fault Memory DIMM
Location: U0.1-P1-C1-M7
4067 0015 Memory DIMM fault Memory DIMM
Location: U0.1-P1-C1-M5
4067 0016 Memory DIMM fault Memory DIMM
Location: U0.1-P1-C1-M2
4067 0017 Memory DIMM fault Memory DIMM
Location: U0.1-P1-C1-M4
4067 0018 Memory DIMM fault Memory DIMM
Location: U0.1-P1-C2-M8
4067 0019 Memory DIMM fault Memory DIMM
Location: U0.1-P1-C2-M6
4067 001A Memory DIMM fault Memory DIMM
Location: U0.1-P1-C2-M1
4067 001B Memory DIMM fault Memory DIMM
Location: U0.1-P1-C2-M3
4067 001C Memory DIMM fault Memory DIMM
Location: U0.1-P1-C2-M7
4067 001D Memory DIMM fault Memory DIMM
Location: U0.1-P1-C2-M5
4067 001E Memory DIMM fault Memory DIMM
Location: U0.1-P1-C2-M2
4067 001F Memory DIMM fault Memory DIMM
Location: U0.1-P1-C2-M4
4067 00B0 Bus controller failure
1. Check for system firmware updates
2. PCI riser card
Location: U0.1-P2
4067 00B1 Bus controller failure
1. Check for system firmware updates
2. PCI riser card
Location: U0.1-P2
3. CEC backplane, U0.1-P1
4067 00B3 Processor/VPD problem detected
1. Check for system firmware updates
2. Processor card 1
Location: U0.1-P1-C1
4067 00B4 Processor/VPD problem detected
1. Check for system firmware updates
2. Processor card 2
Location: U0.1-P1-C2
Chapter 5. Error Code to FRU Index 265