Error Code Description Action/
Possible Failing FRU
B1xx 4603 Service processor firmware corrupted
1. Reload system firmware
2. CEC backplane
Location: U0.1-P1
B1xx 4606 Firmware failure
1. Check for system firmware updates
2. Operator panel
Location: U0.1-L1
3. CEC backplane
Location: U0.1-P1
B1xx 4608 Service processor early termination
1. Reset the system by disconnecting and
reconnecting system power
2. Reload system firmware
3. CEC backplane
Location: U0.1-P1
B1xx 460A TOD clock has been reset
1. Set TOD clock
2. CEC backplane
Location: U0.1-P1
B1xx 460B TOD battery failure TOD battery
Location: U0.1-P1-V3
B1xx 4611 Service processor failure
1. Processor card
Location: U0.1-P1-C1
2. CEC backplane
Location: U0.1-P1
B1xx 4620 Modem configuration failure
1. Check modem configuration files
2. Check for system firmware update
3. Modem
4. CEC backplane
Location: U0.1-P1
B1xx 4621 Modem disconnect failure
1. Check modem configuration files
2. Check for system firmware update
3. Modem
4. CEC backplane
Location: U0.1-P1
B1xx 4622 Service processor failure
1. Operator panel
Location: U0.1-L1
2. Check for system firmware update
3. CEC backplane
Location: U0.1-P1