Service
Request
Number
Description and Action
A03-06x Description: Mezzanine bus address parity error.
A03-07x Description: System bus address parity error. Action: Use “MAP 1230: Linux Platform Error
Problem Resolution” on page 80.
A03-08x Description: Mezzanine bus data parity error. Action: Use “MAP 1230: Linux Platform Error
Problem Resolution” on page 80.
A03-09x Description: System bus data parity error. Action: Use “MAP 1230: Linux Platform Error
Problem Resolution” on page 80.
A03-10x Description: Mezzanine bus time-out, transfer or protocol error. Action: Use “MAP 1230:
Linux Platform Error Problem Resolution” on page 80.
A03-11x Description: System bus time-out error. Action: Use “MAP 1230: Linux Platform Error
Problem Resolution” on page 80.
A03-12x Description: Error on System bus. Action: Use “MAP 1230: Linux Platform Error Problem
Resolution” on page 80.
A03-13x Description: I/O Expansion bus parity error. Action: Use “MAP 1230: Linux Platform Error
Problem Resolution” on page 80.
A03-14x Description: I/O Expansion bus time-out error. Action: Use “MAP 1230: Linux Platform Error
Problem Resolution” on page 80.
A03-15x Description: I/O Expansion bus connection failure. Action: Use “MAP 1230: Linux Platform
Error Problem Resolution” on page 80.
A03-16x Description: I/O Expansion unit not in an operating state. Action: Use “MAP 1230: Linux
Platform Error Problem Resolution” on page 80.
A05-00x Description: Error log analysis indicates an environmental and power warning, but the failure
could not be isolated. Action: Use “MAP 1230: Linux Platform Error Problem Resolution” on
page 80.
A05-01x Description: Sensor indicates a fan has failed. Action: Use “MAP 1230: Linux Platform Error
Problem Resolution” on page 80.
A05-02x Description: System shutdown due to a fan failure. Action: Use “MAP 1230: Linux Platform
Error Problem Resolution” on page 80.
A05-03x Description: Sensor indicates a voltage outside normal range. Action: Use “MAP 1520:
Power” on page 105.
A05-04x Description: System shutdown due to voltage outside normal range. Action: Use “MAP 1520:
Power” on page 105.
A05-05x Description: Sensor indicates an abnormally high internal temperature. Action: Verify that:
1. The room ambient temperature is within the system operating environment.
2. There is unrestricted air flow around the system.
3. All system covers are closed.
4. There are no fan failures.
If none of these problems exist, then proceed with “MAP 1230: Linux Platform Error Problem
Resolution” on page 80.