Service
Request
Number
Description and Action
A0D-05x Description: Service Processor error accessing special registers. Action: Use “MAP 1230:
Linux Platform Error Problem Resolution” on page 80.
A0D-06x Description: Service Processor reports unknown communication error. Action: Use “MAP
1230: Linux Platform Error Problem Resolution” on page 80.
A0D-07x Description: Internal service processor firmware error or incorrect version. Action: Use “MAP
1230: Linux Platform Error Problem Resolution” on page 80.
A0D-08x Description: Other internal Service Processor hardware error. Action: Use “MAP 1230: Linux
Platform Error Problem Resolution” on page 80.
A0D-09x Description: Service Processor error accessing Vital Product Data EEPROM. Action: Use
“MAP 1230: Linux Platform Error Problem Resolution” on page 80.
A0D-10x Description: Service Processor error accessing Operator Panel. Action: Use “MAP 1230:
Linux Platform Error Problem Resolution” on page 80.
A0D-11x Description: Service Processor error accessing Power Controller. Action: Use “MAP 1230:
Linux Platform Error Problem Resolution” on page 80.
A0D-12x Description: Service Processor error accessing Fan Sensor. Action: Use “MAP 1230: Linux
Platform Error Problem Resolution” on page 80.
A0D-13x Description: Service Processor error accessing Thermal Sensor.
Note: If you are servicing a 9076/Nxx system, go to the Service Processor Error Log
(SVP).Action: Use “MAP 1230: Linux Platform Error Problem Resolution” on page 80.
A0D-14x Description: Service Processor error accessing Voltage Sensor.
Note: If you are servicing a 9076/Nxx system, go to the Service Processor Error Log
(SVP).Action: Use “MAP 1230: Linux Platform Error Problem Resolution” on page 80.
A0D-17x Description: Service Processor error accessing serial port. Action: Use “MAP 1230: Linux
Platform Error Problem Resolution” on page 80.
A0D-18x Description: Service Processor detected NVRAM error. Action: Use “MAP 1230: Linux
Platform Error Problem Resolution” on page 80.
A0D-19x Description: Service Processor error accessing Real Time Clock/Time-of-Day Clock. Action:
Use “MAP 1230: Linux Platform Error Problem Resolution” on page 80.
A0D-20x Description: Service Processor error accessing scan controller/hardware. Action: Use “MAP
1230: Linux Platform Error Problem Resolution” on page 80.
A0D-21x Description: Service Processor detect error with Time-of-Day Clock backup battery. Action:
Use “MAP 1230: Linux Platform Error Problem Resolution” on page 80.
A0D-23x Description: Loss of heart beat from Service Processor. Action: Use “MAP 1230: Linux
Platform Error Problem Resolution” on page 80.
A0D-24x Description: Service Processor detected a surveillance time-out. Action: Use “MAP 1230:
Linux Platform Error Problem Resolution” on page 80.
A0D-25x Description: Power Control Network general connection failure. Action: Use “MAP 1230:
Linux Platform Error Problem Resolution” on page 80.
A0D-26x Description: Power Control Network node failure. Action: Use “MAP 1230: Linux Platform
Error Problem Resolution” on page 80.
A0D-29x Description: Service Processor error accessing Power Control Network. Action: Use “MAP
1230: Linux Platform Error Problem Resolution” on page 80.
A0D-30x Description: Non-supported hardware. Action: Use “MAP 1230: Linux Platform Error Problem
Resolution” on page 80.
A0D-31x Description: Error detected while handling an attention/interrupt from the system hardware.
Action: Use “MAP 1230: Linux Platform Error Problem Resolution” on page 80.
Chapter 11. SRNs for Linux 533