Description and Action
A1D-09x Description: A non-critical error has been detected, a service processor error accessing vital
product data EEPROM. Action: Schedule deferred maintenance. Use “MAP 1230: Linux
Platform Error Problem Resolution” on page 80.
A1D-10x Description: A non-critical error has been detected, a service processor error accessing
operator panel. Action: Schedule deferred maintenance. Use “MAP 1230: Linux Platform
Error Problem Resolution” on page 80.
A1D-11x Description: A non-critical error has been detected, a service processor error accessing
power controller. Action: Schedule deferred maintenance. Use “MAP 1230: Linux Platform
Error Problem Resolution” on page 80.
A1D-12x Description: A non-critical error has been detected, a service processor error accessing fan
sensor. Action: Schedule deferred maintenance. Use “MAP 1230: Linux Platform Error
Problem Resolution” on page 80.
A1D-13x Description: A non-critical error has been detected, a service processor error accessing a
thermal sensor. Action: Schedule deferred maintenance. Use “MAP 1230: Linux Platform
Error Problem Resolution” on page 80.
A1D-14x Description: A non-critical error has been detected, a service processor error accessing
voltage sensor. Action: Schedule deferred maintenance. Use “MAP 1230: Linux Platform
Error Problem Resolution” on page 80.
A1D-17x Description: A non-critical error has been detected, a service processor error accessing
serial port. Action: Schedule deferred maintenance. Use “MAP 1230: Linux Platform Error
Problem Resolution” on page 80.
A1D-18x Description: A non-critical error has been detected, a service processor detected NVRAM
error. Action: Schedule deferred maintenance. Use “MAP 1230: Linux Platform Error
Problem Resolution” on page 80.
A1D-19x Description: A non-critical error has been detected, a service processor error accessing real
time clock/time-of-day clock. Action: Schedule deferred maintenance. Use “MAP 1230: Linux
Platform Error Problem Resolution” on page 80.
A1D-20x Description: A non-critical error has been detected: Service processor error accessing scan
controller/hardware. Action: Schedule deferred maintenance. Use “MAP 1230: Linux Platform
Error Problem Resolution” on page 80.
A1D-21x Description: A non-critical error has been detected, a service processor detected error with
time-of-day clock backup battery. Action: Schedule deferred maintenance. Use “MAP 1230:
Linux Platform Error Problem Resolution” on page 80.
A1D-23x Description: A non-critical error has been detected: Loss of heart beat from Service
Processor. Action: Schedule deferred maintenance. Use “MAP 1230: Linux Platform Error
Problem Resolution” on page 80.
A1D-24x Description: A non-critical error has been detected, a service processor detected a
surveillance time-out. Action: Schedule deferred maintenance. Use “MAP 1230: Linux
Platform Error Problem Resolution” on page 80.
A1D-25x Description: A non-critical error has been detected, a power control network general
connection failure. Action: Schedule deferred maintenance. Use “MAP 1230: Linux Platform
Error Problem Resolution” on page 80.
A1D-26x Description: A non-critical error has been detected, a power control network node failure.
Action: Schedule deferred maintenance. Use “MAP 1230: Linux Platform Error Problem
Resolution” on page 80.
A1D-29x Description: A non-critical error has been detected, a service process error accessing power
control network. Action: Schedule deferred maintenance. Use “MAP 1230: Linux Platform
Error Problem Resolution” on page 80.
540 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide