Step 1240-3
1. Turn off the power. Remove the power cord.
2. Remove processor card 1.
3. Reinstall processor card 2 in slot 1.
4. Reattach the power cord. Wait for OK to display in the operator panel.
5. Turn on the power. Attempt to boot to the SMS menus. (The system may stop with an 8-digit error
code before it reaches the SMS menus.)
6. Power off the system using the white button. After the OK displays in the operator panel, look at the
memory configuration/deconfiguration menu.
Are any DIMMs deconfigured or does the error code recorded in “Step 1240-1” on page 74 still
appear?
No Go to “Step 1240-4”.
Yes Go to “Step 1240-6” on page 76.
Step 1240-4
1. Turn off the power. Remove the power cord.
2. Install processor card 1 in slot 2.
3. Reattach the power cord. Wait for OK to display in the operator panel.
4. Turn on the power. Attempt to boot to the SMS menus. (The system may stop with an 8-digit error
code before it reaches the SMS menus.)
5. Power off the system using the white button. After the OK displays in the operator panel, look at the
memory configuration/deconfiguration menu.
Have any DIMMs been deconfigured or does the error code recorded in “Step 1240-1” on page 74
still appear?
No Reseating the processor cards has corrected the problem.
Enable memory repeat gard if necessary.
Go to MAP 0410: Repair Checkout in the RS/6000 Eserver pSeries Diagnostic Information for
Multiple Bus Systems.
Yes Go to “Step 1240-5” on page 76.
Chapter 3. Maintenance Analysis Procedures (MAPs) 75