234 Implementing the IBM Storwize V5000 Gen2 with IBM Spectrum Virtualize V8.1
accessible_vdisk_count 2
compression_supported yes
max_enclosures 10
encryption_supported no
flash_copy_maximum_memory 552.0MB
site_id
site_name
fctargetportmode enabled
compression_total_memory 2047.9MB
At this point, you can configure zones for hosts by using the primary host attach ports (virtual
WWPNs) of the IBM Spectrum Virtualize ports, as shown in bold in the output of Example 5-8
on page 232.
5.4.3 Enabling NPIV on an existing system
When IBM Spectrum Virtualize systems that are running code before 7.7.1 are upgraded to
version 7.7.1 or higher, the NPIV feature is not turned on by default, because it might require
changes to host side zoning. Enabling N_Port ID Virtualization (NPIV) on an existing system
requires that you complete the following steps after meeting the prerequisites:
1. Audit your SAN fabric layout and zoning rules, because NPIV has stricter requirements.
Ensure that equivalent ports are on the same fabric and in the same zone. For more
information, see the topic about zoning considerations for N_PortID Virtualization in IBM
Knowledge Center:
https://ibm.biz/BdjMh2
2. Check the path count between your hosts and the IBM Spectrum Virtualize system to
ensure that the number of paths is half of the usual supported maximum. For more
information, see the topic about zoning considerations for N_Port ID Virtualization in IBM
Knowledge Center:
https://ibm.biz/BdjMh2
3. Run the lstargetportfc command to note down the primary host attach WWPNs (virtual
WWPNs), as shown in bold in Example 5-14.
Example 5-14 Using the lstargetportfc command to get primary host WWPNs (virtual WWPNs)
IBM_2145:ITSO:superuser>lstargetportfc
id WWPN WWNN port_id owning_node_id current_node_id nportid host_io_permitted
virtualized
1 50050768021000EF 50050768020000EF 1 1 1 010200 yes no
2 50050768029900EF 50050768020000EF 1 1 000000 no yes
3 50050768022000EF 50050768020000EF 2 1 1 020200 yes no
4 5005076802A900EF 50050768020000EF 2 1 000000 no yes
5 50050768023000EF 50050768020000EF 3 1 1 0A83C0 yes no
6 5005076802B900EF 50050768020000EF 3 1 000000 no yes
7 50050768024000EF 50050768020000EF 4 1 1 011400 yes no
8 5005076802C900EF 50050768020000EF 4 1 000000 no yes
33 50050768021000F0 50050768020000F0 1 2 2 010300 yes no
34 50050768029900F0 50050768020000F0 1 2 000000 no yes
35 50050768022000F0 50050768020000F0 2 2 2 020300 yes no
36 5005076802A900F0 50050768020000F0 2 2 000000 no yes
37 50050768023000F0 50050768020000F0 3 2 2 011500 yes no
38 5005076802B900F0 50050768020000F0 3 2 000000 no yes
39 50050768024000F0 50050768020000F0 4 2 2 0A82C0 yes no
40 5005076802C900F0 50050768020000F0 4 2 000000 no yes