EasyManuals Logo

IBM System x3650 M4 BD Type 5466 User Manual

IBM System x3650 M4 BD Type 5466
786 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #624 background imageLoading...
Page #624 background image
W.3818005 [W.3818005] The CRTM flash driver could not successfully flash the staging area. The update was
aborted
Explanation: CRTM Update Aborted
Severity: Warning
User response: Complete the following steps:
1. Continue booting system. If system does not reset, manually reset the system.
2. If the error is not reported on the subsequent boot, no additional recovery action is required.
3. If the event persists, continue booting system and reflash UEFI image.
4. (Trained service technician only) Replace the system board.
W.381800D [W.381800D] TPM physical presence is in asserted state
Explanation: TPM physical presence is in asserted state
Severity: Warning
User response: Complete the following steps:
1. Complete any administrative tasks requiring the TPM physical presence switch to be in the "ON" position..
2. Restore the physical presence switch to the "OFF" position and reboot the system.
3. (Trained service technician only) Replace the system board.
W.3938002 [W.3938002] A boot configuration error has been detected.
Explanation: Boot Configuration Error
Severity: Warning
User response: Complete the following steps:
1. F1 Setup -> Save Settings
2. Retry OOB config update
W.50001 [W.50001] A DIMM has been disabled due to an error detected during POST.
Explanation: DIMM Disabled
Severity: Info
User response: Complete the following steps:
1. If the DIMM was disabled because of a memory fault, follow the procedure for that event.
2. If no memory fault is recorded in the logs and no DIMM connector error LEDs are lit, re-enable the DIMM
through the Setup utility or the Advanced Settings Utility (ASU).
3. If problem persists, Power cycle the node.
4. Reset IMM to default settings.
5. Reset UEFI to default settings.
6. Reflash IMM and UEFI firmware.
7. (Trained Service technician only) Replace system board.
W.3818005 W.50001
608
System x3650 M4 BD Type 5466: Installation and Service Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3650 M4 BD Type 5466 and is the answer not in the manual?

IBM System x3650 M4 BD Type 5466 Specifications

General IconGeneral
Form Factor2U Rack
Operating System SupportMicrosoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware vSphere
MemoryUp to 768GB DDR3
StorageUp to 16x 2.5" hot-swap SAS/SATA HDDs/SSDs
Power Supply750W
Network InterfaceIntegrated quad-port Gigabit Ethernet
RAID SupportRAID 0, 1, 10
Remote ManagementIBM IMM2
ProcessorIntel Xeon E5-2600 v2 series