EasyManuals Logo
Home>IBM>Server>System x3650 M4 BD Type 5466

IBM System x3650 M4 BD Type 5466 User Manual

IBM System x3650 M4 BD Type 5466
786 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #734 background imageLoading...
Page #734 background image
201-901-003 Standalone Memory Test Failed
Explanation: Memory Diagnostics Test Failed.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
5. Replace any DIMMS(s) mentioned in error, one by one.
6. Make sure that all DIMMs are enabled in the Configuration/Setup Utility program.
7. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the
next corrective action.
Related Links:
v IBM Support Website
v Latest level of DSA
v Latest level of BMC/IMM
DSA memory stress test results
The following messages can result when you run the memory stress test.
202-000-000 MemStr Test Passed
Explanation: Test Passed.
Severity: Event
Serviceable: No
Recoverable: No
Automatically notify Support: No
Related Links:
v IBM Support Website
v Latest level of DSA
v Latest level of BMC/IMM
201-901-003 202-000-000
718
System x3650 M4 BD Type 5466: Installation and Service Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3650 M4 BD Type 5466 and is the answer not in the manual?

IBM System x3650 M4 BD Type 5466 Specifications

General IconGeneral
BrandIBM
ModelSystem x3650 M4 BD Type 5466
CategoryServer
LanguageEnglish

Related product manuals