7. If you are instructed to return the ServeRAID adapter, follow all packaging
instructions, and use any packaging materials for shipping that are supplied to
you.
Note: When the ServeRAID adapter is removed, software RAID will not be
supported. This system does not support downgrade software RAID function
from hardware RAID configuration.
Results
If you have other devices to install or remove, do so now. Otherwise, go to
“Completing the installation” on page 79.
Installing a hot-swap hard disk drive
Use this information to a hot-swap hard disk drive into the server.
About this task
The following notes describe the type of hard disk drives that the server supports
and other information that you must consider when you install a drive. For a list
of supported drives, see http://www.ibm.com/systems/info/x86servers/
serverproven/compat/us/
v Locate the documentation that comes with the hard disk drive and follow those
instructions in addition to the instructions in this chapter.
v The system supports support up to fourteen 3.5-inch hot-swap SAS/SATA hard
disk drives (two 3.5-inch hot-swap SAS/SATA hard disk drives are located at the
rear of the server).
v All hot-swap drives in the server should have the same throughput speed rating.
Using hard disk drives with different speed ratings will cause all drives to
operate at the throughput speed of the slowest drive.
Attention: To maintain proper system cooling, do not operate the server for more
than 10 minutes without either a drive or a filler panel installed in each bay.
To install a drive in a hot-swap bay, complete the following steps:
Figure 28. ServeRAID adapter removal
44 System x3650 M4 BD Type 5466: Installation and Service Guide