EasyManuals Logo

IBM System x3650 M4 Type 7915 Problem Determination And Service Guide

IBM System x3650 M4 Type 7915
358 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #105 background imageLoading...
Page #105 background image
Table 6. IMM2 error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
General messages
80030012-2301xxxx Sensor OS RealTime
Mod has deasserted.
Info Indicate whether
the system
management
firmware is working
in the state to
support the
realtime OS.
No action; information only.
80070202-0701xxxx Sensor Planar Fault
has transitioned to
critical from a less
severe state.
Error A sensor has
changed to Critical
state from a less
severe state.
1. Check the system-event log.
2. Check for an error LED on the
system board.
3. Replace any failing device.
4. Check for a server firmware update.
Important: Some cluster solutions
require specific code levels or
coordinated code updates. If the
device is part of a cluster solution,
verify that the latest level of code is
supported for the cluster solution
before you update the code.
5. (Trained technician only) Replace
the system board (see “Removing
the system board” on page 290 and
“Installing the system board” on
page 292).
8007020f-2582xxxx Sensor No PCI I/O
has transitioned to
critical from a less
severe state.
Error A sensor has
transitioned to
critical from less
severe.
Complete the following steps for PCI
I/O resource error issue resolution:
1. Understand the I/O resource
requirements in a basic system.
2. Identify the I/O resource
requirements for desired add-in
adapters. For examples, PCI-X or
PCIe adapters.
3. Disable on-board devices that you
can do without and that request I/O.
4. In F1 setup, select the System
Settings Device and I/O Ports
menu
5. Remove adapters or disable slots
until the I/O resource is less than
64 KB.
806f011b-0701xxxx The Front USB
connector has
encountered a
configuration error.
Error The system had
detected an
internal connection
error.
Reseat the front USB cable on the
system board.
806f011b-0701xxxx The Front Video
connector has
encountered a
configuration error.
Error The system had
detected an
internal connection
error.
Reseat the front video cable on the
system board.
Chapter 3. Diagnostics 87

Table of Contents

Other manuals for IBM System x3650 M4 Type 7915

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3650 M4 Type 7915 and is the answer not in the manual?

IBM System x3650 M4 Type 7915 Specifications

General IconGeneral
Form Factor2U Rack
ChipsetIntel C600 series chipset
Operating System SupportMicrosoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware vSphere
ProcessorUp to two Intel Xeon E5-2600 series processors
MemoryUp to 768GB DDR3 (24 DIMM slots)
StorageUp to 16 x 2.5" or 6 x 3.5" SAS/SATA HDDs or SSDs
RAID SupportRAID 0, 1, 10
NetworkFour integrated Gigabit Ethernet ports
Power SupplyUp to two redundant hot-swap 550 W, 750 W, or 900 W power supplies
Expansion SlotsUp to 7 PCIe 3.0 slots
Storage ControllerServeRAID M5110e
ManagementIntegrated Management Module (IMM) v2

Related product manuals