Table 6. IMM2 error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
806f0125-0c01xxxx Front panel entity has
been detected
Absent.
Info A front panel entity
has been detected
absent.
No action; information only.
806f0013-1701xxxx A front panel NMI has
occurred on system
%1.
(%1 =
CIM_ComputerSystem.
ElementName)
Error An operator
information panel
NMI/diagnostic
interrupt has
occurred.
No action; information only.
806f0313-1701xxxx A software NMI has
occurred on system
%1.
(%1 =
CIM_ComputerSystem.
ElementName)
Error A software NMI
has occurred.
1. Check the device driver.
2. Reinstall the device driver.
3. Update all device drivers to the
latest level.
4. Update the firmware (UEFI and
IMM) (see “Updating the firmware”
on page 297).
81030012-2301xxxx OS RealTime Mod
state has asserted.
Info Indicate whether
the system
management
firmware is working
in the state to
support the
realtime OS.
No action; information only.
80070219-0701xxxx Sensor Sys Board
Fault has transitioned
to critical.
Error A sensor has
changed to Critical
state from a less
severe state.
1. Check the system-event log.
2. Check for an error LED on the
system board.
3. Replace any failing device.
4. Check for a server firmware update.
Important: Some cluster solutions
require specific code levels or
coordinated code updates. If the
device is part of a cluster solution,
verify that the latest level of code is
supported for the cluster solution
before you update the code.
5. (Trained technician only) Replace
the system board (see “Removing
the system board” on page 290 and
“Installing the system board” on
page 292).
806f020f-2201xxxx The System %1
encountered a POST
Progress.
(%1 =
CIM_ComputerSystem.
ElementName)
Info A POST progress
has been detected.
(Sensor =
Progress)
No action; information only.
88 IBM System x3650 M4 Type 7915: Problem Determination and Service Guide

Table of Contents

Other manuals for IBM System x3650 M4 Type 7915

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3650 M4 Type 7915 and is the answer not in the manual?

IBM System x3650 M4 Type 7915 Specifications

General IconGeneral
Form Factor2U Rack
ChipsetIntel C600 series chipset
Operating System SupportMicrosoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware vSphere
ProcessorUp to two Intel Xeon E5-2600 series processors
MemoryUp to 768GB DDR3 (24 DIMM slots)
StorageUp to 16 x 2.5" or 6 x 3.5" SAS/SATA HDDs or SSDs
RAID SupportRAID 0, 1, 10
NetworkFour integrated Gigabit Ethernet ports
Power SupplyUp to two redundant hot-swap 550 W, 750 W, or 900 W power supplies
Expansion SlotsUp to 7 PCIe 3.0 slots
Storage ControllerServeRAID M5110e
ManagementIntegrated Management Module (IMM) v2