Table 6. IMM2 error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
806f000f-22010axx System encountered
firmware error - no
video device
detected.
Error A system firmware
error no video
device has been
detected.
This is a UEFI detected event. The
UEFI diagnostic code for this event can
be found in the logged IMM message
text. Please refer to the UEFI
diagnostic code in the "UEFI diagnostic
code" section of the Info Center for the
appropriate user response.
806f000f-22010cxx CPU voltage
mismatch detected
on ABR Status :
Firmware Error.
Error A CPU voltage
mismatch with the
socket voltage has
been detected.
This is a UEFI detected event. The
UEFI diagnostic code for this event can
be found in the logged IMM message
text. Please refer to the UEFI
diagnostic code in the "UEFI diagnostic
code" section of the Info Center for the
appropriate user response.
806f000f-2201ffff The system
encountered a POST
Error.
Error A post error has
been detected.
No action; information only.
806f000f-22010bxx The System %1
encountered a POST
Error.
(%1 =
CIM_ComputerSystem.
ElementName)
Error Firmware BIOS
(ROM) corruption
was detected
during POST.
(Sensor = ABR
Status)
1. Make sure the server meets the
minimum configuration to start
(see “Power-supply LEDs” on page
135).
2. Recover the server firmware from
the backup page:
a. Restart the server.
b. At the prompt, press F3 to
recover the firmware.
3. Update the server firmware to the
latest level (see “Updating the
firmware” on page 297).
Important: Some cluster solutions
require specific code levels or
coordinated code updates. If the
device is part of a cluster solution,
verify that the latest level of code is
supported for the cluster solution
before you update the code.
4. Remove components one at a time,
restarting the server each time, to
see if the problem goes away.
5. If the problem remains, (trained
service technician) replace the
system board (see “Removing the
system board” on page 290 and
“Installing the system board” on
page 292).
90 IBM System x3650 M4 Type 7915: Problem Determination and Service Guide

Table of Contents

Other manuals for IBM System x3650 M4 Type 7915

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3650 M4 Type 7915 and is the answer not in the manual?

IBM System x3650 M4 Type 7915 Specifications

General IconGeneral
Form Factor2U Rack
ChipsetIntel C600 series chipset
Operating System SupportMicrosoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware vSphere
ProcessorUp to two Intel Xeon E5-2600 series processors
MemoryUp to 768GB DDR3 (24 DIMM slots)
StorageUp to 16 x 2.5" or 6 x 3.5" SAS/SATA HDDs or SSDs
RAID SupportRAID 0, 1, 10
NetworkFour integrated Gigabit Ethernet ports
Power SupplyUp to two redundant hot-swap 550 W, 750 W, or 900 W power supplies
Expansion SlotsUp to 7 PCIe 3.0 slots
Storage ControllerServeRAID M5110e
ManagementIntegrated Management Module (IMM) v2