D Scan resume timer (RESUME)
Selects the scan resume time from a pause after the received
signal disappears.
• 0 SEC : Scan resumes immediately after the received
signal disappears.
• 1–5 SEC : Scan pauses 1–5 sec. after the received signal
disappears.
(default: 2 sec.)
• HOLD : Scan remains paused on the received signal
according to the scan pause timer even if it dis-
appears. Rotate [DIAL] to resume manually.
Scan resume timer must be set shorter than scan pause
timer
(previous item), otherwise this timer cannot be acti-
vated.
D Memory bank link function (B-LINK)
Sets the memory bank link function ON (default) and OFF.
The link function provides continuous bank scan, scanning all
channels in the selected banks during bank scan.
• Bank link setting
q Push [](2) or [](8) to select the bank that you want to
change the link setting.
w Push [ ](5) to enter bank setting.
e Push [](2) or [](8) to select the setting.
r Push [ ](5) to set and return to the BANK selection
screen.
t Push [](2) or [](8) to select next bank and repeat
steps w to r, or push
[MENU ] to exit MENU screen
operation.
122
12
MENU SCREEN OPERATION

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Icom IC-E80D and is the answer not in the manual?

Icom IC-E80D Specifications

General IconGeneral
BrandIcom
ModelIC-E80D
CategoryTransceiver
LanguageEnglish

Related product manuals